16.1. OPERATION
Position the remote control toward the infrared receiving window of the device.
Check that there is no obstacle between the remote control and the infrared
receiver to disturb the transmission.
1. Display of the ambient temperature
2. Boost: activation of the boost
3. Selection of the Auto, Comfort, Eco, Frost Protection modes
4. Adjustment of the setting temperature desired and the boost duration
1
2
3
4
2
Infrared receiving window
17. INFRARED REMOTE CONTROL (OPTIONAL)
Your towel rails can be managed by a remote control with infrared transmission through its IR receiver
located on the front of the controller.
Full manual on www.jaga.com / QR-code
18. PILOT WIRE (FOR FRANCE)
18.1. REMOTE CONTROL
From Auto mode, the device can be controlled by a central control unit through a pilot wire, in which
case the different operating modes will be remotely enabled by the programmer.
In general, a pilot wire control system makes it possible to impose externally a lowering of the tempe-
rature setpoint, combined with the internal programming.
By pressing
or
, you can change temporarily the desired temperature. This modification will be
automatically cancelled at the next order sent by the central control unit or the transition to 00:00.
NOTE: The cursor corresponding to the operating mode, is blinking during the duration of the tempo-
rary derogation.
18.2. LOAD SHEDDING
In case of over consumption, an energy power manager or a disconnector doesn’t trigger a trip of the
general (example: simultaneous operating of your various household appliances and others).
This allows you to reduce the energy power subscribed and therefore optimize your subscription with
your energy provider.
The controllers are designed to operate with load shedding systems with pilot wire only.
Orders sent by the pilot wire are executed by the device’s electronic controller which will apply set-
point corresponding to the order sent.
The « Stop » order corresponds to the load shedding. When this order is received, the device swit-
ches to “standby” and then returns to the initial operating mode.
18.3. OTHER REMOTELY MANAGEMENT BY POWER SHUTDOWN
THE POWER SUPPLY OF THE DEVICE SHOULD BE CUT WHEN WORKING ON THE ELECTRICAL
SYSTEM ONLY. THE LOAD SHEDDING WITH FREQUENT MECHANIZED POWER SHUTDOWNS CAN
CAUSE DETERIORATION OF THE DEVICE DEPENDING OF THE QUALITY OF SWITCHING ELEMENTS
USED. THIS TYPE OF DETERIORATION WOULD NOT BE COVERED BY THE MANUFACTURER’S
WARRANTY.
IF STOP OR STANDBY ORDERS SHOULD BE FREQUENTLY OPERATED, YOU MUST USE THE PILOT
WIRE.