35
PROBLEMA
Dirty water
Excessive water consumption
Low water flow from the hydromassage
nozzles
No water flow
PROBABLE CAUSE
Filter clogged
Insufficient water treatment
High content of solid material in water
Manutenzione scorretta
Leak on delivery line, outlet line, connec-
tions
Excessive evaporation and/or water over-
flow
Low water level
Filter clogged
Jets partially closed
Suction or drain pipes partially clogged
Pump operates at a speed that is too low
Pump gaskets worn or damaged
Voltage too low
No current
Pump off
Motor not connected
Main switch turned off
Residual current operated circuit breaker
(RCCB) has tripped
Faulty pump or motor
Filtering pump not working
(too high wa-
ter temperature, flow switch and/or faulty
temperature probe).
SOLUTION
Clean or replace filter
See chapter on water treatment
See the instructions regarding Mainte-
nance
Repair the leak
Use the hot tub cover
Set a water temperature set point lower
Fill until covering the highest nozzles
Clean or replace filter
Open the jets
*
*
*
Contact an electrician or the electric pow-
er utility
Turn main switches ON
Press the button
or
/
Check the motor connection
Turn on the switch
Reset the RCCB
*
See "smart winter" mode section relative
to the over heating during the filtering
cycles and/or the section relative to the
alarm signalling.
Troubleshooting (also refer to the chapter on abnormal operating conditions)
Summary of Contents for Skylounge
Page 2: ...2...
Page 9: ...9 1 2 3 clack 1...
Page 10: ...10 click 2 3 clack 1 4 5x40 mm 2a 2b 1 2a 2b 1 6 6 4 5 2...
Page 11: ...11 10 m A B 3 optional en option fakultativ opcional optional en option fakultativ opcional...
Page 12: ...12 2 9x19 mm 2 5 mm 1 2 3 4...
Page 84: ...84 ON smart winter...
Page 85: ...85...
Page 86: ...86 B2 dip switch 2 L1 L2 Jacuzzi Jacuzzi Europe S p A...
Page 87: ...87...