32
NOTE:
press and hold the button until you reach the desired val-
ue; by releasing the button and pressing it again, the adjustment is
made in the opposite direction.
X
Press the “
Pump
”
button again and the selected value is
confirmed, and the cycle
start delay
is programmed
with re-
spect to the "0" time
(
sy
parameter where “y” indicates the num-
ber of hours).
WARNING:
time "0" is the instant when power is supplied to the hot
tub through the main switch or the time when the parameters are
stored; if, for example, the value "4" is set as the start delay of the
cycle, this means that the filtration will start 4 hours after turning
on the hot tub, or after storing the parameters; it is also possible to
reduce the parameter value to 0 “
s
”: In this case, the filtration cycle
will start immediately.
X
Set the start delay
(from a minimum of 0 to a maximum of 12)
using the “
Up/Down
”
button and confirm the value with the
“
Pump
”
button to store the values inserted and to exit the
programming mode.
When the function is active, the LED of the respective symbol
lights up
(if it flashes, it means that the cycle has been suspended;
see relative section).
X
During the filtering cycles,
“Flt”
appears on the screen.
NOTES
If no key is touched for about 5 seconds, the device exits “parame-
ter-setting” mode.
If there is a power outage, the data in the memory is saved, but the
time “0” will become the moment at which the electricity comes
back on. Therefore, it may be necessary to turn the main switch up
the line from the hot tub off and back on to re-align the cycle start
delay with the memorized parameters.
It is possible to vary the filtering cycle setting parameters at any
time by following the procedure provided at the beginning of this
chapter.
By modifying these parameters, time “0” is “shifted”
to the time in which the new values are saved.
Q
S
USPENDING
THE
FILTERING
CYCLES
X
Activating the hydromassage stops the filtration cycle, but it
resumes about 5 minutes after the function has turned off.
Moreover, with these models, the “silence” mode also sus-
pends the filtering cycle (refer to the respective section for fur-
ther details).
X
The filtering cycle may be suspended by the anti-freeze pro-
tection
(“Smart Winter”)
or due to overheated water. Refer to the
respective chapters.
Q
C
LEARRAY
P
RO
3
TECT
™
(
WHERE
EXPECTED
).
The Clearray Pro3tect
™
system helps to disinfect and purify water,
thus reducing the need for chemical products.
X
The Clearray Pro3tect™ system operates automatically and is
dependent on activation of the filtration pump during the filter-
ing cycle; it remains off when the hydromassage is on; Clearray
Pro3tect™ begins operating once again 40 minutes after switch-
ing off the aforementioned functions (where a filtering cycle is
active).
Hydromassage activation
X
This function is activated by pressing the “
Pump
”
button
(display B) or the
button (display A)
(activation is also sig-
nalled by the respective LED - display B - which may also be flash-
ing; on displays A, the button briefly lights up blue, then returns to
white).
B
A
X
To activate the function:
- briefly press the “
Pump
”
button (display A) to turn pump
on/off
(the button briefly lights up blue, then returns to white);
- press the “
Pump
”
button (display B) to turn pump on/off;
- The function turns off automatically after 20 minutes (if not turned
off by the user).
- If the electrical energy limiter has been activated, turning on a hy-
dromassage pump will switch off the heater.
Underwater spotlight
X
Press the
“Pump”
button (display B) or the
button
(display A) to activate the spotlight on the tub wall
(activation is
also signalled by the respective LED - display B - which may also be
flashing; on displays A, the button briefly lights up blue, then returns
to white).
X
The spotlight will stay on for 3 hours, but it can be turned off
before by pressing the key again
(please refer to the user manual
for information on operating the various colour sequences).
alternatively
Summary of Contents for Skylounge
Page 2: ...2...
Page 9: ...9 1 2 3 clack 1...
Page 10: ...10 click 2 3 clack 1 4 5x40 mm 2a 2b 1 2a 2b 1 6 6 4 5 2...
Page 11: ...11 10 m A B 3 optional en option fakultativ opcional optional en option fakultativ opcional...
Page 12: ...12 2 9x19 mm 2 5 mm 1 2 3 4...
Page 84: ...84 ON smart winter...
Page 85: ...85...
Page 86: ...86 B2 dip switch 2 L1 L2 Jacuzzi Jacuzzi Europe S p A...
Page 87: ...87...