Page 75
J-400
during a programmed filter cycle. These pumps draw water from footwell
suction fitting and through a secondary water polishing bag filter and
additional filter. The exclusive footwell “sweeper” suction fitting enhances
filtration in the footwell area by creating a “swirling” water motion to
maximize particle agitation and pickup.
A.
Cleaning the filters and filter bag
To ensure optimum performance:
1. The ProClarity™ filter cartridge (A) must be
cleaned every three months and replaced every
two years.
2. The ProClarity Depth filter (B) must be replaced
every 3 to 4 months.
3. The ProClarity filter canister (C) can be rinsed
when the filters are cleaned.
4. The ProClear II skimming filter cartridge (D)
must be cleaned every three months and replaced every
two years.
5. The ProClarity debris bag (E) should be checked and
emptied monthly.
To accomplish this, refer to the following filter cleaning procedure.
Note:
Do not attempt to wash the ProClarity depth filter (B) and the
ProClear/ProClarity debris bag (E) or it will come apart!
B.
Cleaning the Filters/Debris bag:
A
DANGER:
TURN POWER TO SPA OFF! TO DECREASE
RISK OF DEATH, DROWNING, OR ENTRAPMENT, NEVER
OPERATE SPA WHEN FILTER IS NOT PROPERLY INSTALLED
OR IF SKIMMER ASSEMBLY IS DAMAGED OR ALTERED!
B
(Spa
Shell)
Lift the cover upward to
access filter cartridges.
C
Remove the ProClarity
debris bag from clips
and then clean out
debris.
D
(Spa Shell)
Rotate each filter
cartridge handle
counterclockwise to
unthread from mating
wall fitting.
A
B
C
D
E
Debris
Bag