J-200
14.
System Test 1:
Assure there is no water dripping from the seal
compression nut (7). If water is visible, STOP and tighten the
compression nut (7) using a pair of channel lock pliers to a maximum
of 1/4 turn. If that does not fix the leak, then repeat quartz tube
maintenance process from step 1 through step 13. Make sure there
is no water leaking before proceeding to step 15.
15.
System Test 2:
Reconnect the CLEAR
RAY
System to the controller.
Turn breaker back ON. Turn on the pump to circulate the water
through the CLEAR
RAY
System. Wait for 5 minutes and assure no
water is dripping. If water is visible, STOP, fix the leak by repeating
quartz tube maintenance process from step 1 through step 14.
Make
sure there is no water visi
ble and turn the pump and breaker
OFF, disconnect the
CLEAR
RAY System to the controller
BEFORE proceeding to step 16.
16. Reconnect the bulb socket (5) to the new UV bulb (4) make sure you
use the latex glove provided when handling the UV bulb.
Note:
Align pins on UV bulb (4) to the receptacle holes on the bulb
socket (5) before inserting the pins completely into socket holes. Failure
to do so will damage the UV bulb.
WARNING:
DO NOT TOUCH THE NEW UV LAMP WITH
YOUR BARE HAND. Oil on your skin will cause hot spot on
the UV bulb and shorten the life of your UV bulb. Use the
provided latex glove to handle the UV bulb.
!
17. Slide the new UV bulb (4) back inside the quartz tube, Figure 3.
18. Reinstall the black bulb boot (8) back over the quartz seal
compression nut (7).
19. Reinstall the enclosure cover (10) with gasket (9) and secure with
the screws.
20. Reconnect the CLEAR
RAY
System to the controller and turn on the
power to the spa.
21. Properly dispose of the old UV bulb.
WARNING:
This CLEAR
RAY
System includes a UV bulb,
which contains mercury. Dispose of the bulb in accordance
with disposal laws. See www.lamprecycle.org.
!
22. Once power is activated you can check the ballast
(12), Figure 7, to see if the CLEAR
RAY
System
is functioning. A solid green light indicates that the
CLEAR
RAY
System is being provided power and
should always be on. A solid red light indicates that
UV bulb is activated.
Figure 7
120 - 230V
Indicator
Lights