J-200
13.4 CLEARRAY® Lamp Replacement and Quartz Tube
Maintenance
Important:
It is
MANDATORY
that the UV bulb is replaced and the
quartz tube be cleaned every 12 months to maintain optimum
performance.
!
DANGER:
TURN THE SPA BREAKER TO THE OFF
POSITION!
!
WARNING:
DRAIN THE SPA IF YOU ARE REPLACING OR
CLEANING THE QUARTZ TUBE!
!
WARNING:
ALLOW LAMP TO COOL DOWN PRIOR TO
REMOVING FROM QUARTZ TUBE.
!
DANGER:
NEVER LOOK AT THE LIT BULB. THIS CAN
CAUSE SEVERE EYE DAMAGE OR BLINDNESS.
UV BULB REPLACEMENT AND QUARTZ TUBE MAINTENANCE:
Note:
Location of CLEAR
RAY
System and connection may vary by
model.
1. Turn the breaker to the spa OFF. DRAIN YOUR
SPA. Disconnect the CLEAR
RAY
System from the
controller, Figure 2.
Note:
If you are only replacing the UV bulb then the spa
does not have to be drained. You will need to drain it if
you are replacing or cleaning the quartz tube.
DANGER:
NEVER REMOVE COVER WITHOUT FIRST
TURNING OFF AT POWER SOURCE AND DRAINING THE
SPA .
!
2. Once the UV bulb has cooled off remove the CLEAR
RAY
System
enclosure cover (10) and gasket (9) by removing the four screws
(11).
1
2
3
4
5
6 7
8
9 10
12
13
11
Figure 1
WARNING!
DONOT LOOK AT LIT BULB
SEVERE EYE DAMAGE
OR BLINDNESS CAN OCCUR
SPA CONTROLLER
Figure 2
Connection
UV Unit
42