3. Remove the filter cartridge by rotating it counterclockwise to
unthread it from the filter wall fitting (Figure B). Then lift it straight up
to remove from filter well (Figure C).
4. Using a garden hose with a high-pressure nozzle, rinse debris from
the filter pleats beginning at the top and working your way downward
(Figure D). Continue, one section at a time, until you have rinsed all
of the filter’s pleats.
To ensure optimum performance, clean skimmer basket and filter
cartridge once a month or as necessary, depending on use.
J-210 models include filters on their footwell suction covers
(shown right) that prevent debris from entering the pump when
operating. These filters must remain in place to protect the
components from debris entrapment/damage. They should be
cleaned every 2 months, or when weak pump performance is
observed.