J-200
11.5
Filtration Modes for Spas
During the filtration/heating cycle the Jets pump 1 low speed will activate.
To set a time for the first filtration/heating cycle, simply turn power on to
the spa two minutes prior to the desired time. Example: If you desire your
first filtration/heating cycle to begin at 10:00 AM turn off power to the spa
and turn it back on again at 9:58 AM.
Note:
Start time is approximate and may vary slightly from day to day.
Standard Filtration/Heating Modes (F1-F3)
(Heater automatically turns on during any heat call while in any Standard
mode).
F1
4 hours of filtration/heating per day (one 2-hour cycle
every 12 hours).
F2
6 hours of filtration/heating per day (one 2-hour cycle
every 8 hours).
F3
8 hours of filtration/heating per day (one 2-hour cycle
every 6 hours).
Economy Filtration/Heating Modes (F4-F6)
(Heater can only turn on during an active filter cycle while in
any Economy mode).
F4
4 hours of filtration/heating per day (one 2-hour cycle
every 12 hours).
F5
6 hours of filtration/heating per day (one 2-hour cycle
every 8 hours).
F6
8 hours of filtration/heating per day (one 2-hour cycle
every 6 hours).
Lock Modes (L1-L2)
L1
Lock Out (disables all spa functions to permit filter
cleaning).
L2
Lock Mode (disables the jets and light buttons to
prevent unauthorized use of spa). Filtration/heating
cycle will continue to operate as programmed in
this mode. The temperature display flashes when this function is
enabled. Example: the “F3” filtration/heating cycle was enabled
prior to choosing lock mode. The spa continues to perform the
“F3” cycle until lock mode is canceled, allowing another cycle to be
selected.
Note:
To exit a Lock Mode you will need to re-enter the filtration/heating
modes and select a cycle from F1-F6.
29