J-200
16.0 Circuit Board Diagrams
16.1 North American J-235, J-245, J-275 and J-280 Models
This wiring diagram is used for the 240V 60 Hz North American spa
models.
OR
Mini-Din Cable provides constant 12 V
AC from
yellow transformer wires
Mini-Din Control Panel Cable
Light DCU
1
2
3
4
5
6
7
8
9
10
POWER
EXP BAR
EXP BAR
Stereo
Power Supply
CLEAR
R
AY
GRN
TB1
Standard 240 V
AC, 3-W
ire Connection (60 Hz, 1-Phase Service)
USE COPPER CONDUCT
ORS ONL
Y. WIRE SIZE MUST
BE
APPROPRIA
TE
PER NEC
AND/OR LOCAL
CODES.
THE MAX SUPPL
Y CONNECT
OR
AMP
ACITY
IS 60A.
THE
AMPERE RA
TING OF SUPPL
Y CONDUCT
OR
OVERCURRENT
PROTECTIVE DEVICE IS 60A.
RED
RED
J6
BLK J5
WHT
WHT
RED
BLK
BLK
WHT
BLK
RED
RED
BLK
BLK
BLK
2
1
Hi - limit / freeze sensor
Temperature sensor
J1
J2
J3
F1 30A, 250V SC-30
Pump 1
Circ Pump
Pump 2
Transformer
240 V
AC
J4
F1
JP1
4 2
3 1
6
5
8
7
HI
HI
LO
Control Panel
J20
K1
K2
K3
K4
K5
K6
K7
K8
J21
J11
J12
J13
J14
J15
J16
J17
J18
J19
J7
J8
J9
J10
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1.
This device may not cause harmful
interference. 2.
This device must accept any inteferenc
e
received including interference that ma
y
cause undesired operation.
Heater 5.5 kW 240 V
AC
WHT
BLK
LED Lighting System DCU
EXTERNAL SERVICE PANEL BOX DISCONNECT MEANS MUST BE LOCATED NO CLOSER THAN 5 FT. (1.52m) FROM THE INSIDE WALLS OF THE SPA AND WITHIN SIGHT OF SPA
MAIN POWER
ON//OFF SHUTOFF
SWITCH
Logic Jumper Settings
JP1 1-2 ON =
40A
Logic
JP1 1-2 OFF =
50A
Logic (Factory Default Setting)
JP1 3-4 ON =
2 Pump Operation
JP1 3-4 OFF =
1 Pump Operation
JP1 5-6 ON =
60A
Logic (Remove JP1 1-2 Jumper)
JP1 5-6 OFF =
Leave Of
f for 40A
or 50A
Logic
JP1 7-8 ON =
Celsius
Temperature Display
JP1 7-8 OFF =
Fahrenheit
Temperature Display
WHT
BLK
C
(Not of
fered on all models)
(Not of
fered on
all models)
Flow sensor
(Not of
fered
on all models)
Ports 1-10 power spa lights, waterfall lights and step lights on applicable models
48