HC: CONTACTOR (HEATER) RH: RINSE
HEATERS. (6) 2500 W.
CB-1: OVER CURRENT, CURRENT
CIRCUIT BREAKER,
15AMPS RATING R1 & R2:
CONTACTORS (WASH &
RINSE MOTORS)
M-SW: MASTER SWITCH ON-OFF
1 ELS: CONTROL, HIGH LEVEL FILL,
LOW LEVEL CUT-OFF IN WASH
TANK & RINSE TANK HEAT, LOW
VOLTAGE SENSOR, 24 V. TO
PROBE
H-SW: HEAT & LIGHT SWITCH R-3:
CONTACTOR (WASH HEATER) W-THS &
R-THS: INDEPENDENT THERMOSTAT
CONTROL WASH & RINSE TANK HEAT;
WASH HEAT WH: WASH
HEATER (1)1500 W.
S-SW: START SWITCH, STARTS THE
AUTOMATIC CYCLE WHEN
THROWN TO THE CLOSE SIDE OF
TH
TH: TIMER HOLD: TIMER MOTOR RUNS
ONE HALF CYCLE, THEN OPENS
TH TO COMPLETE ONE MACHINE
CYCLE
TW & TR: TIMER WASH & TIMER RINSE
CONTROLLED BY CAMS DRIVEN
BY THE TIMER MOTOR.
MW-SW: MANUAL OPERATION WASH
SWITCH: IN THE OFF POSITION
FOR AUTOMATIC OPERATION: ON-
FOR-MANUAL OPERATION, ON
LOCKS OUT RINSE MOTOR
MR-SW: MANUAL RINSE & PILL
SWITCH, SPRING RETURN, LOCKS
IN R-2 THROUGH 1-ELS, UNTIL
MACHINE FILLS TO HIGH LEVEL
PROBE IN WASH TUB.
2-ELS: CONTROLS THE WATER LEVEL
IN THE RINSE TANK THROUGH
LOW VOLTAGE SENSOR, 24 V. TO
PROBE FOR OPENING THE
SOLENOID VALVE
51