RINSE HEATERS (6) 2200 W HC:
CONTACTOR
CB 1: OVER CURRENT CIRCUIT
BREAKERS-15A.
R1&2: CONTACTOR M SW: MASTER
SWITCH ON OFF
1 ELS, CONTROL, HIGH LEVEL FILL,
LOW LEVEL CUT OFF IN WASH
TANK & RINSE TANK HEAT. LOW
VOLTAGE SENSOR, 24V. TO
PROBE
H SW: HEAT & LIGHT SWITCH
W THS & R-THS: INDEPENDENT
THERMOSTAT CONTROL WASH &
RINSE TANK HEAT WASH
HEATER. (1) 1500 W.
S-SW: START SWITCH - STARTS THE
AUTOMATIC CYCLE WHEN
THROWN TO THE CLOSE SIDE OF
TH: TIMER HOLD, - TIMER MOTOR
RUNS ONE HALF CYCLE, THEN
OPENS - TH TO COMPLETE ONE
MACHINE CYCLE,
TW: TIMER WASH & TR: TIMER RINSE
CONTROLLED BY CAMS DRIVEN
BY THE TIMER MOTOR
MW-SW: MANUAL OPERATION WASH
SWITCH IN THE OFF POSITION
FOR AUTOMATIC OPERATION. ON
FOR MANUAL OPERATION.
MR-SW: MANUAL RINSE & FILL
SWITCH, SPRING RETURN, LOCKS
IN R2 THROUGH 1-ELS, UNTIL
MACHINE FILLS
TO
HIGH LEVEL
PROBE IN WASH TANK.
48
Summary of Contents for 100 B/PRB
Page 6: ......
Page 26: ......
Page 46: ...45 BOOSTER TANK HEATER ELEMENT P N 0060500 WASH TANK HEATER ELEMENT P N 0058000...