RH RINSE HEATERS ((6) 2500 W
HC: CONTACTOR (HEATE R) CB 1
OVER CURRENT, CIRCUIT
BREAKER 15AMP RATING
Rl & R2 CONTACTORS (WASH &
RINSE MOTOR)
M SW MASTER SWITCH ON OFF
1 ELS. CONTROL. HIGH LEVEL FILL,
LOW LEVEL CUT-OFF IN WASH
TANK & RINSE TANK HEAT, LOW
VOLTAGE SENSOR, 24 V. TO
PROBE
H SW: HEAT & LIGHT SWITCH
W THS & R THS INDEPENDENT
THERMOSTAT CONTROL WASH &
RINSE TANK HEAT. WASH
HEATER. (1)1500 W.
R3. CONTACTOR (WASH HEATER)
S.SW: START SWITCH, STARTS THE
AUTOMATIC CYCLE WHEN
THROWN TO THE CLOSE SIDE OF
TH
TH: TIMER HOLD: TIMER MOTOR
RUNS ONE HALF CYCLE, THEN
OPENS TH TO COMPLETE ONE
MACHINE CYCLE
TW & TR: TIMER WASH & TIMER
RINSE: CONTROLLED BY CAMS
DRIVEN BY THE TIMER MOTOR
MW-SW: MANUAL OPERATION WASH
SWITCH: IN THE OFF POSITION
FOR AUTOMATIC OPERATION ON
FOR MANUAL OPERATION. ON
LOCKS OUT RINSE MOTOR
MR SW: MANUAL RINSE & FILL
SWITCH. SPRING RETURN,
LOCKS IN R-2 THROUGH 1 ELS,
UNTIL MACHINE FILLS TO HIGH
LEVEL PROBE IN WASH TUB
2 ELS: CONTROLS THE WATER LEVEL
IN THE RINSE TANK THROUGH
LOW VOLTAGE SENSOR. 24 V. TO
PROBE FOR OPENING THE
SOLENOID VALVE
50
Summary of Contents for 100 B/PRB
Page 6: ......
Page 26: ......
Page 46: ...45 BOOSTER TANK HEATER ELEMENT P N 0060500 WASH TANK HEATER ELEMENT P N 0058000...