TROUBLE SHOOTING GUIDE
PROBLEM
CAUSE
SOLUTION
1- No Voltage to dishwasher,
Nothing on machine
a. Customer's fuse blown or
a. Replace or reset.
operates.
circuit breaker tripped.
2- Machine circuit breaker
2- Turn on or reset.
tripped or turned off.
3- Voltage to machine low or
3- Contact your electrician
circuit to machine broken.
and/or power company for
repair.
Will not fill with electrical
1- Water hand valve off.
1- Turn hand valve on.
power applied even though
other components work.
2- Master switch not on or
2- Turn on or replace.
(B Model)
faulty.
3- Fill switch faulty or loose
3- Replace switch or wire or
wire connection.
connection terminal.
4- Solenoid valve does not
4- See instruction page
operate.
concerning the Solenoid
valve.
5- Water level control faulty
5- See page on water.
6- Y strainer clogged.
6- Turn water to machine
off, remove plug & strainer
screen, clean & replace.
Will not fill with electrical
1- Customer's water hand
1-Tum hand valve on.
power applied even though
valve off.
other components work
(PRB Model)
2- Master switch not on or
2- Turn on or replace.
faulty.
3- Fill switch faulty or loose
3- Replace switch or wire or
wire connection.
connection terminal.
4- Rinse motor not operating.
4- Check connection and
voltage to motor repair or
replace as necessary.
5- Water level control does not
5- See instruction page
maintain the water level in the
concerning the water level
rinse tank.
control for PRB Models.
6- Solenoid Valve does not
6- See instruction page con-
operate
cerning Solenoid Valve.
7- Y-strainer clogged.
7- Turn off water to machine,
remove plug. prepare to
catch hot water & strainer
screen, clean & replace.
30