TROUBLE SHOOTING GUIDE
PROBLEM
CAUSE
SOLUTION
Rinse pump leaks.
1- Impeller seal is worn.
1- See instruction page on
PRB Models only.
ceramic replacement
2- Impeller ceramic is worn or
2- Same as 1.
scored.
Indicator light(s) do
1- Lights faulty or poor connec-
1- Replace or correct
not glow at any time.
tion.
connection.
None of the automatic
1- Start switch faulty.
1-Check switch. Replace if
functions work (wash, rinse).
necessary, see instructions
page concerning replace
ment of switches in control
panel.
2-
Wire connections poor.
2- Correct connection.
3- Timer rinse or wash micro-
3- See instruction page
switch faulty.
concerning timer &
motor.
Vacuum breaker leaks
1- Limed up.
1- Disassemble:
a. Remove top using
flat jaw wrench or
channel locks.
b. Remove poppet.
c. Clean poppet & V.B.
top & body.
d. Replace parts removed.
2- Faulty.
2-Replace needed parts or
whole VB.