Alarm system JA-65 MAESTRO
- 8 -
MFM53003
List of control panel programmable parameters
Function
sequence
options
factory d.
note
Enrolling of detectors and controllers
1
1
&
7
scroll, 2 erase pos., 3
controllers, 4 all
- w.
R
module only
Hard-wired zone input setting
60 nn xyz
nn
– zone n.,
x
– triggering,
y
– reaction,
s
- section
all off
w.
H
module only
Exit delay
20x
x
= 1 to 9 (x 10sec.)
30sec.
Entrance delay
21x
x
= 1 to 9 (x 10sec.)
30sec.
Alarm duration
22x
x
= 1 to 8 (min.), 0=10s, 9=15min
4min.
Function of PgX output
23x
x
= 0 to 8 (0-Chime, 1-Fire, 2-
Arm, 3-Panik, 4-Alarm, 5-Door,
6-Home, 7-No AC, 8-Phone
Chime
split system has
different setting
Function of PgY output
24x
x
= 0 to 8 (0-Chime, 1-Fire, 2-
Arm, 3-Panik, 4-Alarm, 5-Door,
6-Home, 7-No AC, 8-Phone
Arm
split system has
different setting
Voice m. & tel. Numbers editable in the user mode
25x
251 = YES 250 = NO
NO w.
X
module only
Radio signal jamming regular testing
26x
261 = YES 260 = NO
NO w.
R
module only
Regular communication check enabled
27x
271 = YES 270 = NO
NE w.
R
module only
RESET enabled
28x
281 = YES 280 = NO
YES
Subsystem arming enrollment
290
will enroll to sub-control panel as wireless controller
w.
R
module only
Control panel enrollment to a UC-2xx, subsystem,...
299
will send enrolling signal
w.
R
module only
No code requested (effects
,
,
, F4, F8 & F9)
30x
301 = YES 300 = NO
YES
Partial (Home) arming enabled (
)
31x
311 = YES 310 = NO
YES
Siren alarm enabled
32x
321 = YES 320 = NO
YES
Exit delay audible indication enabled
33x
331 = YES 330 = NO
YES
Partial arming exit delay audible indication
34x
341 = YES 340 = NO
NO
Entrance delay audible indication enabled
35x
351 = YES 350 = NO
YES
Arming & disarming chirp sounds enabled
36x
361 = YES 360 = NO
NO
Siren in Disarm & Partial arming enabled
37x
371 = YES 370 = NO
YES
Wireless siren alarm enabled
38x
381 = YES 380 = NO
YES
w.
R
module only
Indication of system problems when arming
39x
391 = YES 390 = NO
NO
Split control panel (A, B & C sections)
690x
6901 = YES 6900 = N0
NO
Only first source of alarm is recorded
691x
6911 = YES 6910 = NO
NO
Alarm triggered by opened zone when arming
692x
6921 = YES 6920 = NO
NO only
if
391
Audible panic alarm
693x
6931 = YES 6930 = NO
NO
Next delay wireless detectors
694x
6941 = YES 6940 = NO
NO
Communication loss alarm
696x
6961 = YES 6960 = NO
YES
Entering the programming mode by SC+MC/UC
697x
6971 = YES 6970 = NO
NO
Addressing of wireless controllers to sections
63 nns
nn
– controller n.,
s
- section
all A
split & R module
Automatic arming/disarming setting
64nahhmm
n
- 0-9,
a
-action #,
hh
-hours,
mm
-min.
all off
New Service Code setting
5 nSC nSC
nSC = new Service Code
6060
enter code twice
Real time and date setting
4 hh mm DD MM RR
00 00 01 01 00
User Mode entering
6999
Switching to the User mode
-