16. Trouble shooting table 

 

Problem 

possible cause 

solution 

alarm after first powering  

the control panel is not in factory default setting  

perform a factory default reset 

connected JA-60E keypad has no 
function 

connecting cable does not connect the corresponding positions in the 
keypad and in the control panel (1-1, 2-2, 3-3, 4-4)  

Check the colors of the cores in the cable 
and positions on each side 

impossible to enroll a wireless item 
 

location of the item is not suitable and the radio signal level is too low 
(too far away or  an obstacle is in the way of communication) 

change location of the item, (fix it in the 
new place temporary at first and then try it) 

a fault is indicated on the keypad 
and it is beeping 

check display for the reason of the trouble. Press key N to disable 
beeping. The trouble information is stored in the event memory and it 
can be reviewed entering F4 anytime in the future 

check the reason of the trouble in user 
manual and fix it, or call the installer  

If JA-65X is used, telephone line 
failure is indicated and the phone 
works as normal 

when you make a phone call longer than 15 minutes, it is interpreted 
by the system that the tel. line is not ready. 

if this problem repeats, disable tel. line 
checking in programming mode 

PIR movement detector repeatedly 
triggers alarms with no visible 
reason  

check if there are: animals in the protected area (mice...), sudden 
changes of temperature or intense air circulation, movement of 
objects with temperature of about 37°C etc.   

increase detector’s immunity (internal 
setting), change location of the detector or 
use an optional sensor’s lens  

fault or alarm C is indicated  

blown fuse in the control panel or radio communication jamming  

PC with Comlink SW gives details 

system does not communicate 
with connected PC 

the PC-60A cable is not connected to the correct COM connector on 
the PC 

check the connection or select the  port 
number in SW manually 

problem is not in this list 

call installer or the distributor for advice  

local hot line number: 

 

 

 

17. Possibilities to extend the system 

The JA-65 alarm system is a kit which can be tailor 

configured according to the size of the house or the needs of 
the user. It can combine wireless and wire operated 
components. 

 
17.1  Extension of the system with a subsystem 

 

An additional JA-65 or JA-60 control panel can be enrolled as 

a subsystem to the control panel (see 11.12.). Each system 
then works as an independent system. However, any event in 
the subsystem (alarm, tampering, failure or low battery) will 
trigger the same kind of event on the main control panel (the 
main control panel will display "J" as the event source). The 
main control panel will not indicate the number of the item 
which triggered the event, but this information is available on 
the subsystem’s control panel. 
 Using this method, multiple level subsystems can be chained. 

 

Warning: never enroll the top level control panel as a 
subsystem of the lower level control panel. This would create 
endless circle for the data and such an alarm system chain 
would not work properly. 

 

 

17.2 Extension of the system with a communicator 

 

GSM communicator JA-60GSM 

By using GSM communicator JA-60GSM you will get supervision 
over the system wherever you are. Communicator sends SMS 
messages, calls to predefined telephone numbers and plays 
audible warning, communicates with 2 CMS, allows remote 
access from a phone’s keypad and can be set and operate via 
web page 

www.GSMlink.cz

.

 

 
Digital communicator JA-65X 

Communicator JA-65X can communicate with a Monitoring 
Station, send  two voice messages, send five SMS messages 
via SMS server (if it is supported in your country or dial a 
numeric Pager). It can also communicate with a remote  PC 
(using ComLink SW and a JA-60U modem). By remotely 
connected PC it is possible to set and/or operate the control 
panel.

 

 

17.3 Brief overview of parts suitable for the JA-63 
system 
 

 

The brief overview you got along with this manual includes the 

basic assortment of accessories. Jablotron is systematically 
introducing new and improved  items to the market. You can get 
the most current information from your distributor or you can visit 
Jablotron’s Internet home page at: www.jablotron.com 

 

 

Summary of Contents for MAESTRO JA-65

Page 1: ...JA 65 MAESTRO Alarm system installation manual...

Page 2: ......

Page 3: ...audible indication 12 11 19 Arming and disarming chirps with hard wired siren 12 11 20 Siren alarm in Disarm Partial arming 12 11 21 Wireless siren alarm 12 11 22 Indication of system problems when a...

Page 4: ...ireless output modules Hard wired input module JA 65H has 8 input loops with programmable triggering NC balanced or double balanced and programmable reactions Up to two JA 65H hard wired input modules...

Page 5: ...e should be connected to the metal case Instructions use flexible 2 core size from 0 75 to 1 5 mm 2 double insulated power cord The system should not share a fuse 10 A max with any other household ite...

Page 6: ...nal siren output In the normal mode it has the U terminal voltage In the alarm mode it has a GND terminal potential Connect an ordinary external siren to U and SIR terminals max load 0 7 A A back up s...

Page 7: ...ed backup period a 12V back up battery from 1 3Ah to 45Ah can be used instead A battery larger than 7Ah must be installed in an external case and the case must be equipped with tamper protection The c...

Page 8: ...module only No code requested effects F4 F8 F9 30x 301 YES 300 NO YES Partial Home arming enabled 31x 311 YES 310 NO YES Siren alarm enabled 32x 321 YES 320 NO YES Exit delay audible indication enabl...

Page 9: ...its enrollment signal The siren will send the signal only if it has no current communication with any other control panel This protects you from enrolling your neighbor s siren Enrollment is complete...

Page 10: ...ice message and telephone numbers of the built in dialer If the changes are enabled then programming sequences for number programming voice message recording and dialer testing are accessible in the U...

Page 11: ...panel was enrolled to position c3 scroll to this position in the enrolling mode and holding key 2 will erase the master control panel as a controller 11 12 Enrollment of the control panel to a UC 2xx...

Page 12: ...s after arming if any component of the system is not ready for arming Cause of the problem for example permanently triggered detector lost communication etc will remain displayed on the keypad If the...

Page 13: ...en to enter the programming mode SC 6060 MC 1234 must be set F0 6060 1234 Factory default setting disabled Note it has no influence on the user mode entering F0 MC 11 30 Addressing of wireless detecto...

Page 14: ...ed wireless controller or siren signal receiving will be similarly indicated Some detectors JA 60P JA 60N JA 60B etc have an extra testing mode which is usually activated for 5 minutes after the detec...

Page 15: ...amples There is a comprehensive help file in the Comlink program virtual control panel access complete events list item testing window RF signal oscilloscope programming dialogs map of the system show...

Page 16: ...distributor for advice local hot line number 17 Possibilities to extend the system The JA 65 alarm system is a kit which can be tailor configured according to the size of the house or the needs of th...

Page 17: ...e outputs PgX PgY Chime Fire Arm Panic Alarm Door Home AC failure Phone siren output 12 V 0 7 A Wireless outputs module 65R transmits signals for siren and PgX PgY data for UC 2xx receivers Events mem...

Reviews: