Note: if the Master or Service code is forgotten when the reset
is disabled, the reset of the control panel will be possible only
by the manufacturer.
11.11. Controlling of a subsystem
sequence: 2 9 0
A wireless master control panel receives event signals (alarms,
tampering, faults, low battery) from a JA-6x subsystem if
enrolled - see 11.1 and 11.12.
This will cause the same kind of event on the master control
panel and
J
will be indicated as the source of the event on the
keypad.
The master and slave control panels can be either armed and
disarmed as two independent systems or the slave system can
follow the arming and disarming of the master. If the master
should rule arming of the slave subsystem, make the following
settings:
a. enroll a subsystem to the master‘s
J
position,
b. place the master panel into the programming
mode (P is indicated),
c. enter the enrolling mode in the sub-control panel
(pressing key 1 while in the programming mode)
d. enter 290 on the master control panel – this way
the master will be enrolled to the slave sub-
control panel as a wireless controller (to the first
free position of c1 to c8)
e. turn both systems to standby mode and check
that the subsystem will be armed (in 2 seconds)
after arming of the master control panel. Check
the same for disarming
Notes:
•
Master control panel generates wireless commands
Arm and Disarm the same way as a remote control
RC-40. The control panel transmits these commands
only if it has a subsystem enrolled in its position J.
•
The Arm command is generated when the master
control panel is completely armed and also at the end
of an alarm while the system remains completely
armed (automatic alarm timeout). The Disarm
command is generated when the master control panel
is disarmed, when it is partly armed (home arming or
one section arming if it is split) and also in the end of
an alarm while the system is disarmed (manual
termination of the alarm).
•
The subsystem can also be operated by its other
controllers (remote controls, keypads) if there are
any. For better understanding you can simply
imagine, that the master control panel is just another
remote control.
Controlling
of the subsystem by the master control panel
can
be disabled
by erasing the corresponding cN position in the
sub-control panel. For example if the master control panel was
enrolled to position c3, scroll to this position in the enrolling
mode and holding key 2 will erase the master control panel as a
controller.
11.12. Enrollment of the control panel to a UC-2xx or
to a master control panel
sequence: 2 9 9
The control panel can send wireless data to output modules
UC–216, UC–222 and UC-260. It can also work as a subsystem
of another JA-65 or JA-60 control panel.
Enter the enrolling mode of the
UC receiving device
and then
enter
299
and the control panel will transmit the enrollment
signal.
If you want to enroll a
subsystem
to your control panel, enter
the enrolling mode on the MASTER control panel (see 11.1.)
and then enter sequence 299 in the programming mode of the
sub control panel.
If the system is split the sub control panel enrolls to the common
shared section.
11.13. No code requested for
,
,
,
(F1, F2,
F3), F4, F8 & F9
sequence: 3 0 x
If this parameter is enabled no code is requested for functions
F1, F2, F3, F4, F8 and F9 (or the
,
,
keys on the
keypad). When this parameter is disabled these functions (keys)
can be used only when followed by a code (Master or User) –
see the following table:
Factory default setting: no code requested
Note: this feature is also selectable on the JA-60D wireless
keypad and it is independent from the control panel setting.
11.14. Partial (Home) arming with
(F2) (non split
control panel)
sequence: 3 1 x
In partial arming, the control panel reacts only to detectors
addressed to section A (see 11.2 and 11.31) and it ignores the
triggering of detectors in section B or C (except smoke and gas
detectors). Partial arming can be disabled with this sequence.
options:
3 1 1
partial
arming
enabled
3 1 0
partial arming
disabled
Factory default setting: partial arming enabled
11.15. Hard wired siren alarm enabled
sequence: 3 2 x
The SIR siren output is activated when any alarm is triggered
(except silent Panic alarm). The siren indication can be disabled
with this parameter.
options:
3 2 1
siren
enabled
3 2 0
siren
disabled
Factory default setting: siren enabled
11.16. Exit delay audible indication
sequence: 3 3 x
The exit delay can be indicated by the „beeping“ of the keypad
(for the last five seconds, the beeping is faster). The audible
indication can be disabled with this setting.
options:
3 3 1
indication
enabled
3 3 0
indication
disabled
Factory default setting: indication enabled
function / setting
300
301
arming
„code“
F 1
partial arming
F 2 „code“
F 2
door opening
F 3 „code“
F 3
memory reading
F 4 „code“
F 4
Appliance control
F 8 „code“ 0
F 8 „code“ 1
F 80
F 81
message listening
F 9 „code“
F 9