Alarm system JA-65 MAESTRO 

- 11 - 

MFM53003 

Note: if the Master or Service code is forgotten when the  reset 
is disabled, the reset  of the control panel will be possible only 
by the manufacturer.  

 

11.11. Controlling of a subsystem 

 

sequence:  2 9 0 

A wireless master control panel receives event signals (alarms, 
tampering, faults, low battery) from a JA-6x subsystem if 
enrolled - see 11.1 and 11.12. 

This will cause the same kind of event on the master control 
panel and  

J

 will be indicated as the source of the event on the 

keypad.  

The master and slave control panels can be either armed and 
disarmed as two independent systems or the slave system can 
follow the arming and disarming of the master. If the master 
should rule arming of the slave subsystem, make the following 
settings:  

 

a.  enroll a subsystem to the master‘s 

position, 

b.  place the master panel into the programming 

mode (P is indicated), 

c.  enter the enrolling mode in the sub-control panel 

(pressing key 1 while in the programming mode) 

d.  enter 290 on the master control panel – this way 

the master will be enrolled to the slave sub-
control panel as a wireless controller (to the first 
free position of c1 to c8)  

e.  turn both systems to standby mode and check 

that the subsystem will be armed (in 2 seconds) 
after arming of the master control panel. Check 
the same for disarming  

Notes: 

• 

Master control panel generates wireless commands 
Arm and Disarm the same way as a remote control 
RC-40. The control panel transmits these commands 
only if it has a subsystem enrolled in its position J.  

• 

The Arm command is generated when the master 
control panel is completely armed and also at the end 
of an alarm while the system remains completely 
armed (automatic alarm timeout). The Disarm 
command is generated when the master control panel 
is disarmed, when it is partly armed (home arming or 
one section arming if it is split) and also in the end of 
an alarm while the system is disarmed (manual 
termination of the alarm). 

• 

The subsystem can also be operated by its other 
controllers (remote controls, keypads) if there are 
any. For better understanding you can simply 
imagine, that the master control panel is just another 
remote control. 

 

Controlling

 of the subsystem by the master control panel 

can 

be disabled

 by erasing the corresponding cN position in the 

sub-control panel. For example if the master control panel was 
enrolled to position c3, scroll to this position in the enrolling 
mode and holding key 2 will erase the master control panel as a 
controller. 

 

11.12. Enrollment of the control panel to a UC-2xx or 
to a master control panel 

 

sequence:  2 9 9 

The control panel can send wireless data to output modules 
UC–216, UC–222 and UC-260. It can also work as a subsystem 
of another JA-65 or JA-60 control panel. 

Enter the enrolling mode of the 

UC receiving device

 and then 

enter 

299

 and the control panel will transmit the enrollment 

signal. 

If you want to enroll a 

subsystem 

to your control panel, enter 

the enrolling mode on the MASTER control panel (see 11.1.) 
and then enter sequence 299 in the programming mode of the 
sub control panel. 

If the system is split the sub control panel enrolls to the common 
shared section. 

 

11.13. No code requested for 

  (F1, F2, 

F3),  F4, F8 & F9   

 

sequence:  3 0 x 

If this parameter is enabled no code is requested for functions 

F1, F2, F3, F4, F8 and F9 (or the 

 

keys on the 

keypad). When this parameter is disabled these functions (keys) 
can be used only when followed by a code (Master or User) – 
see the following table: 

  

Factory default setting: no code requested 

Note: this feature is also selectable on the JA-60D wireless 
keypad and it is independent from the control panel setting.  

11.14. Partial (Home) arming with 

 (F2)   (non split 

control panel)   

sequence:  3 1 x 

In partial arming, the control panel reacts only to detectors 
addressed to section A (see 11.2 and 11.31) and it ignores the 
triggering of detectors in section B or C (except smoke and gas 
detectors). Partial arming can be disabled with this sequence.  

options: 

3 1 1

 partial 

arming 

enabled

 

3 1 0

 

 

partial arming 

disabled

 

Factory default setting: partial arming enabled 

 

11.15. Hard wired siren alarm enabled 

sequence:  3 2 x 

The SIR siren output is activated when any alarm is triggered 
(except silent Panic alarm). The siren indication can be disabled 
with this parameter. 

options: 

3 2 1

 siren 

enabled

 

3 2 0

 siren 

disabled

  

Factory default setting: siren enabled 

 

11.16. Exit delay audible indication 

 

sequence:  3 3 x 

The exit delay can be indicated by the  „beeping“ of the keypad 
(for the last five seconds, the beeping is faster). The audible 
indication can be disabled with this setting.  

options: 

3 3 1

 indication 

enabled

 

3 3 0

 indication 

disabled

  

Factory default setting: indication enabled 

function / setting 

300 

301 

arming 

„code“ 

F 1 

partial arming 

F 2 „code“ 

F 2 

door opening 

F 3 „code“ 

F 3 

memory reading 

F 4 „code“ 

F 4 

Appliance control 

F 8 „code“ 0 
F 8 „code“ 1 

F 80 
F 81 

message listening 

F 9 „code“ 

F 9 

Summary of Contents for MAESTRO JA-65

Page 1: ...JA 65 MAESTRO Alarm system installation manual...

Page 2: ......

Page 3: ...audible indication 12 11 19 Arming and disarming chirps with hard wired siren 12 11 20 Siren alarm in Disarm Partial arming 12 11 21 Wireless siren alarm 12 11 22 Indication of system problems when a...

Page 4: ...ireless output modules Hard wired input module JA 65H has 8 input loops with programmable triggering NC balanced or double balanced and programmable reactions Up to two JA 65H hard wired input modules...

Page 5: ...e should be connected to the metal case Instructions use flexible 2 core size from 0 75 to 1 5 mm 2 double insulated power cord The system should not share a fuse 10 A max with any other household ite...

Page 6: ...nal siren output In the normal mode it has the U terminal voltage In the alarm mode it has a GND terminal potential Connect an ordinary external siren to U and SIR terminals max load 0 7 A A back up s...

Page 7: ...ed backup period a 12V back up battery from 1 3Ah to 45Ah can be used instead A battery larger than 7Ah must be installed in an external case and the case must be equipped with tamper protection The c...

Page 8: ...module only No code requested effects F4 F8 F9 30x 301 YES 300 NO YES Partial Home arming enabled 31x 311 YES 310 NO YES Siren alarm enabled 32x 321 YES 320 NO YES Exit delay audible indication enabl...

Page 9: ...its enrollment signal The siren will send the signal only if it has no current communication with any other control panel This protects you from enrolling your neighbor s siren Enrollment is complete...

Page 10: ...ice message and telephone numbers of the built in dialer If the changes are enabled then programming sequences for number programming voice message recording and dialer testing are accessible in the U...

Page 11: ...panel was enrolled to position c3 scroll to this position in the enrolling mode and holding key 2 will erase the master control panel as a controller 11 12 Enrollment of the control panel to a UC 2xx...

Page 12: ...s after arming if any component of the system is not ready for arming Cause of the problem for example permanently triggered detector lost communication etc will remain displayed on the keypad If the...

Page 13: ...en to enter the programming mode SC 6060 MC 1234 must be set F0 6060 1234 Factory default setting disabled Note it has no influence on the user mode entering F0 MC 11 30 Addressing of wireless detecto...

Page 14: ...ed wireless controller or siren signal receiving will be similarly indicated Some detectors JA 60P JA 60N JA 60B etc have an extra testing mode which is usually activated for 5 minutes after the detec...

Page 15: ...amples There is a comprehensive help file in the Comlink program virtual control panel access complete events list item testing window RF signal oscilloscope programming dialogs map of the system show...

Page 16: ...distributor for advice local hot line number 17 Possibilities to extend the system The JA 65 alarm system is a kit which can be tailor configured according to the size of the house or the needs of th...

Page 17: ...e outputs PgX PgY Chime Fire Arm Panic Alarm Door Home AC failure Phone siren output 12 V 0 7 A Wireless outputs module 65R transmits signals for siren and PgX PgY data for UC 2xx receivers Events mem...

Reviews: