Alarm system JA-65 MAESTRO 

- 4 - 

MFM53003 

This product is  to be installed by professional installers only. 

The manufacturer assumes no liability for damages caused by 
incorrect installation or improper use of this system. 

 

 

1.  Architecture of the control panel 

 

The JA-65 "Maestro" is a fully programmable control panel with 
building block architecture.  This allows the JA-65 to be tailored 
to particular installation requirements. The Maestro can operate 
as a wireless, wired or combined system.  
The JA-65K  metal box has a built in electronic power supply. 
There is space for a 12V, 7Ah  back up battery.  The 16 zone 
control panel’s main board is installed in the internal platform. 
The main board does not have any physical zone inputs. This 
allows you to co figurate the control panel by using the following 
modules: 

• 

Radio communicating module JA-65R 

can enroll wireless 

items (JA-60): up to 16 detectors, up to 8 controllers 
(remote controls or wireless keypads), JA-60A  wireless 
sirens and UC family wireless output modules. 

• 

Hard-wired input module JA-65H 

has 8 input loops with 

programmable triggering (NC, balanced or double balanced) 

and programmable reactions. Up to two JA-65H  hard-wired 
input modules can be used in the control panel. 

• 

GSM dialer JA-60GSM

 sends SMS messages, calls to 

predefined telephone numbers and plays audible warning, 
communicates with 2 CMS, allows remote access from a 
phone’s keypad and can be set via web page. 

• 

Telephone communicator JA-65X

 can communicate with 

a Monitoring Station, send  voice messages and dial a 
numeric Pager. It can also communicate with a remote  PC 
(using ComLink SW and a JA-60U modem). 

• 

Operation and programming

 is possible via the JA-60E 

keypad (or by its wireless option, JA-60F). The control panel 
can also be operated by a RC-40, RC-22 or RC-60 remote 
control, by input loop or by a JA-60D wireless keypad. 
Operation and programming is also possible via a PC using 
ComLink SW. 

 
    This allows the JA-65 to operate as a wireless (16 detectors), 
wired (8 or 16 inputs) or combined system. An additional JA-63 
or JA-65 subsystem control panel can expand the system. The 
control panel can be split in to two independent sections with a 
shared common area.

  

 

 

 

Summary of Contents for MAESTRO JA-65

Page 1: ...JA 65 MAESTRO Alarm system installation manual...

Page 2: ......

Page 3: ...audible indication 12 11 19 Arming and disarming chirps with hard wired siren 12 11 20 Siren alarm in Disarm Partial arming 12 11 21 Wireless siren alarm 12 11 22 Indication of system problems when a...

Page 4: ...ireless output modules Hard wired input module JA 65H has 8 input loops with programmable triggering NC balanced or double balanced and programmable reactions Up to two JA 65H hard wired input modules...

Page 5: ...e should be connected to the metal case Instructions use flexible 2 core size from 0 75 to 1 5 mm 2 double insulated power cord The system should not share a fuse 10 A max with any other household ite...

Page 6: ...nal siren output In the normal mode it has the U terminal voltage In the alarm mode it has a GND terminal potential Connect an ordinary external siren to U and SIR terminals max load 0 7 A A back up s...

Page 7: ...ed backup period a 12V back up battery from 1 3Ah to 45Ah can be used instead A battery larger than 7Ah must be installed in an external case and the case must be equipped with tamper protection The c...

Page 8: ...module only No code requested effects F4 F8 F9 30x 301 YES 300 NO YES Partial Home arming enabled 31x 311 YES 310 NO YES Siren alarm enabled 32x 321 YES 320 NO YES Exit delay audible indication enabl...

Page 9: ...its enrollment signal The siren will send the signal only if it has no current communication with any other control panel This protects you from enrolling your neighbor s siren Enrollment is complete...

Page 10: ...ice message and telephone numbers of the built in dialer If the changes are enabled then programming sequences for number programming voice message recording and dialer testing are accessible in the U...

Page 11: ...panel was enrolled to position c3 scroll to this position in the enrolling mode and holding key 2 will erase the master control panel as a controller 11 12 Enrollment of the control panel to a UC 2xx...

Page 12: ...s after arming if any component of the system is not ready for arming Cause of the problem for example permanently triggered detector lost communication etc will remain displayed on the keypad If the...

Page 13: ...en to enter the programming mode SC 6060 MC 1234 must be set F0 6060 1234 Factory default setting disabled Note it has no influence on the user mode entering F0 MC 11 30 Addressing of wireless detecto...

Page 14: ...ed wireless controller or siren signal receiving will be similarly indicated Some detectors JA 60P JA 60N JA 60B etc have an extra testing mode which is usually activated for 5 minutes after the detec...

Page 15: ...amples There is a comprehensive help file in the Comlink program virtual control panel access complete events list item testing window RF signal oscilloscope programming dialogs map of the system show...

Page 16: ...distributor for advice local hot line number 17 Possibilities to extend the system The JA 65 alarm system is a kit which can be tailor configured according to the size of the house or the needs of th...

Page 17: ...e outputs PgX PgY Chime Fire Arm Panic Alarm Door Home AC failure Phone siren output 12 V 0 7 A Wireless outputs module 65R transmits signals for siren and PgX PgY data for UC 2xx receivers Events mem...

Reviews: