Jabiru Aircraft
Pty Ptd
Installation Manual
Jabiru 2200 Aircraft Engine
REVISION
0 1 2
Dated : March 2006
Page:
42
\\Gateway\library\files\engine_manuals\2200_engine_manuals\Hydraulic_Lifters\Working copies\HL_Installation_Manual_2200_Rev_0.doc
Print Date: 3/8/2006 1:56:00 PM
j) Ensure the fuel line from fuel pump to the carburettor is connected & protected by
fireproof sleeve.
k) Ensure that the fuel overflow line is in place, and secured to vent overboard.
Figure 20. Oil Collector Bottle
l) Fit the oil over flow bottle to the firewall by drilling and Riveting oil bottle holder in place
using 73AS 6-6 rivets. Refer to photo.
m) Connect the oil breather line from the engine breather.
n) Ensure that the oil overflow line is in place and vents overboard.
o) Fit Scat hoses from NACA duct to Air Inlet Housing Assembly, from hot air muff to
carburettor heat inlet on the hot air mixer box and from the hot air mixer box to
carburetor.
Note It is most important to remove any sharp edges or lips off the inside of the mixer
box cover. See Photos below
Oil collector bottle
Oil vent line from
engine breather
Oil vent line –
venting overboard