Software
22
CANio 250 Quickstart Manual, version 1.2
Description of the Reset:
The CANio 250 is being initialized completely. In case that a configuration has
been stored, the CANio 250 will be initialized with this configuration. In case
that no configuration has been stored, or a stored one has been declared inva-
lid, the CANio 250 will be initialized with the factory default values (see 5.1.11).
The digital outputs will be initialized with their
“configured” default values.
Description of the limited Reset:
In case of the limited Reset, the I/O functionality will not be initialized:
The configuration of the digital inputs and outputs is not changed.
The digital outputs are not changed.
The parameters of the CAN messages the CANio 250 is using are initialized:
CAN identifiers
Event Timer of the CAN messages
Inhibit Time of the CAN messages
After a configuration has been stored, these objects are initialized with the
stored configuration. In case that no configuration has been stored, or a stored
one has been declared invalid, the CANio 250 will be initialized with the default
values (see 5.1.11).