Operation programming
Enter the measured flow.
Shift to the next digit by pushing the DISP key.
*Pushing the EXT key, the programming is cancelled.
Push the start stop key to return to the wait state.
The programming is stored as "SAVE" indication appears on the screen.
The maximum flow can be checked at each unit.
*
Always try to change a flow rate by stroke rate. Changing the stroke length, the
flow rate per shot is changed.
Unit change
GPH, L/h or mL/m cycles through every time the DISP key is pushed. To
display the maximum flow rate at each unit, follow the above calibration proce
-
dure.
spm indication
The screen shows an actual spm in operation when both the EXT and DOWN
keys are pressed for 3 seconds. 0spm will be shown after the pump has
stopped.
Before shipping, every pump is regulated by spm adjustment so as to meet a
required flow rate at 100% stroke rate indication. Note that spm at the same
stroke rate (%) may differ at each pump accordingly.