Operation programming
Push the start/stop key.
The pump starts to run.
• The LED blinks at each shot.
EXT operation
The pump operation is controlled by the external (pulse) signal.
■ EXT mode
Set the upper limit spm and enter EXT mode. Note that the pump starts to run
in sync with the external signal as entering EXT mode.
NOTE
•
Manual operation stroke rate is applied as the EXT upper limit spm. For example,
even if a multiplier or a divisor is set to run the pump at 100% (360spm), the pump
does not run over 50% (180spm) as long as manual stroke rate is 50%.
•
A stroke rate skips from 100 to 0.1% by pushing the UP key once. Pay attention to this
point when programming a stroke rate for the prevention of erroneous programming.
Enter manual mode.
Enter the manual mode to indicate a stroke
rate on the screen.
•
Push the start/stop key when "MULT",
"DIV", "ANA-R" or "ANA-V" is on the
screen.
•
When "STOP" or "-STOP" appears on the
screen, see "STOP function cancellation"
on 62 page and release the STOP function.