User mode
The following features can be programmed. Get access to User mode via the
wait state in the manual mode.
•
STOP function
The pump stops running while receiving the external signal via the STOP
terminal.
• Pre-STOP function
The STOP LED lights orange while the pump receiving the external signal via
the Pre-STOP terminal. The pump does not stop running.
•
OUTPUT function
The pump sends out signals via the OUTPUT terminal in sync with pump
shots or the STOP signal.
•
ANA-V/-R selection
Select either "ANA-V" or "ANA-R" for the EXT mode.
•
Buffer ON/OFF selection
Excessive external signals that are not reflected to the MULT or DIV operation
can be stored. Activate or inactivate the buffer.
•
PIN number entry
A PIN is required to release a keypad lock state.
NOTE
The ANA-V/-R selection is available only when "ANA-V" or "ANA-R" has been selected
in the EXT mode selection. The Buffer ON/OFF selection is available only when "DIV"
or "MULT" has been selected.
or
SET
SET
SET
SET
1
2
2
1
2
2
or
EXT mode selection
User mode
ANA-V/-R selection
Buffer ON/OFF
selection
Operation programming