78
Troubleshooting
States
Possible causes
Solutions
Liquid leaks. Loose fit of the fitting or the air vent
body
•
Retighten them.
Loose fit of the pump head
•
Retighten the pump head. See
page 37.
O rings or valve gaskets are not
installed.
•
Install O rings and valve gaskets.
Diaphragm is broken.
•
Replace the diaphragm.
Excessive discharge pressure
•
Check that a discharge line is not
closed.
•
Check if tubing is not clogged.
Key opera-
tion is inef-
fective.
Keypads are locked.
•
Release the keypad lock.
The pump
does not run.
The pump is in a wait state.
•
Enter the pump into an operation
mode.
The pump has not received the
external signal in the EXT mode.
•
Check wiring.
EXT mode programming has not
finished.
•
Complete EXT mode program-
ming.
The pump
does not
receive the
external
signal.
The signal has not been sent to the
pump.
•
Check wiring.
The pump
does not
store EXT
mode pro-
gramming.
EXT mode programming has not
been stored to the pump.
•
Push the start/stop key after pro-
gramming.
Summary of Contents for EWN -B16 TC