16
STARTING AND STOPPING THE ENGINE
FROM THE DIGITAL CONTROL PANEL
Procedure for start-up from the main IVECO
MOTORS control panel
(supplied on demand)
Make sure that the electrical switch indicating ENGINE ROOM -
BRIDGE on the Relay Box unit (normally located in the engine room) is
in the BRIDGE position, then proceed as follows:
1. Lift the protective cover over the key switch (8), insert the key and
turn it to the right to position
8B
.
2. Make sure that the instruments with analogue displays are showing
values that conform with the relevant physical parameters.
3. Wait for the beeper to stop sounding and for the alarm indicator
lights to switch off, with the exception of the “Alternator
malfunction” and “Low oil pressure” indicators. At the same time,
check that the indicator test has been performed successfully (see
the section on RECOGNIZING ALARMS).
4. Turn the key to position
8C
; once the engine has started, release
the key and do not accelerate.
5. Make sure that the instruments with analogue displays are showing
values that conform with the relevant physical parameters
(temperature, battery voltage and oil pressure).
6. If the engine does not start, after releasing the key it will only be
possible to turn it back to the start position after first returning the
switch to the rest position
8A
.
1. Engine coolant temperature indicator - 2. Lubrication circuit pressure
indicator - 3. Service and alarm signals - 4. Rev counter - 5. Supercharged
air pressure indicator - 6. Voltmeter - 7. Alpha-numeric display - 8. Key
switch to start/stop the engine - 9. Accessory function programming
button - 10. Button used to scroll through and select additional
information - 11. Button to reset the “planned maintenance” indicator -
12. Button to disable the beeper- 13. Beeper.
1
2
4
6
5
8
9
11
12
13
3
3
10
7
04_357_N
8A
8B
8C
04_356_N
Detail of the key switch