12
STARTING AND STOPPING THE ENGINE
FROM THE ANALOGUE CONTROL PANEL
Procedure for start-up from the main IVECO
MOTORS control panel
(supplied on demand)
Make sure that the electrical switch indicating ENGINE ROOM -
BRIDGE on the Relay Box unit (normally located in the engine room) is
in the BRIDGE position, then proceed as follows:
1. Lift the protective cover over the key switch (8), insert the key and
turn it to the right to position
8B
.
2. Make sure that the analogue instruments are showing values that
conform with the relevant physical parameters (temperature,
battery voltage and oil pressure).
3. Wait for the beeper to stop sounding and for the alarm indicator
lights on the indicator module (5) to switch off, with the exception
of the “alternator recharge” and “low oil pressure” indicators. At
the same time, check that the indicator test has been performed
successfully (information on how to interpret this test and
indications on the module are given in the relevant paragraph).
4. Turn the key to position
8C
; once the engine has started, release
the key and do not accelerate.
5. Make sure that the analogue instruments are showing values that
conform with the relevant physical parameters (temperature,
battery voltage and oil pressure).
6. If the engine does not start, after releasing the key it will only be
possible to turn it back to the start position after first returning the
switch to the rest position
8A
.
1. Coolant temperature indicator - 2. Rev counter and hour counter -
3. Voltmeter - 4. Beeper - 5. Indicator and alarm module - 6. Engine oil
pressure indicator - 7. Control panel instrument light switch - 8. Key
switch to start/stop the engine - 9. Button to stop the engine -
10. Button to disable the beeper.
1
2
3
4
5
6
7
8
9
10
04_354_N
8A
8B
8C
04_356_N
Detail of the key switch