3298 Family Rev. 4/07
37
Fig. 33
Table 7A
Failure Symptoms Due to Dry Run Operation
Poor lubrication or dry run operation of 3298 liquid lubricated bearing surfaces results in a significant increase of heat generation. The
lack of cooling flow through the pump also causes significant temperature increase of the bearings. This temperature increase causes
damage to the surrounding parts as described and shown in Fig. 33: (Numbers in Fig. 33 correspond to numbers described below).
1.
The plastic surrounding the outboard thrust bearing may be melted.
2.
The plastic surrounding the carbon or silicon carbide impeller radial bearings may be melted.
3.
The plastic surrounding the inboard thrust bearings may be melted.
4.
If the impeller seizes on the shaft due to excessive heat, the shaft may spin in the shaft spider, wearing the inside diameter of
the shaft spider.
REMEDY
A.
Install dry run protection device like a power monitor (refer to appendix for more information on power monitors)
B.
Modify process system or controls to eliminate dry run operation.
C.
Change bearing material to DryGuard™ coated silicon carbide if silicon carbide bearings were initially installed in the pump.
Summary of Contents for Goulds Pumps V 3298
Page 6: ...6 3298 Family Rev 4 07 ...
Page 26: ...26 3298 Family Rev 4 07 ...
Page 32: ...32 3298 Family Rev 4 07 ...
Page 38: ...38 3298 Family Rev 4 07 ...
Page 112: ...112 3298 Family Rev 4 07 ...
Page 115: ...3298 Family Rev 4 07 115 7 ...
Page 116: ...INTERCHANGEABILITY 3298 XS GROUP 116 3298 Family Rev 4 07 ...
Page 117: ...INTERCHANGEABILITY 3298 S GROUP 3298 Family Rev 4 07 117 7 ...
Page 119: ...INTERCHANGEABILITY 3298 L GROUP 3298 Family Rev 4 07 119 7 ...
Page 120: ...INTERCHANGEABILITY SP 3298 S GROUP 120 3298 Family Rev 4 07 ...
Page 121: ...INTERCHANGEABILITY V 3298 S GROUP 3298 Family Rev 4 07 121 7 ...
Page 122: ...INTERCHANGEABILITY V 3298 M GROUP 122 3298 Family Rev 4 07 ...
Page 124: ...124 3298 Family Rev 4 07 ...
Page 125: ...APPENDIX I 3298 HYDRAULIC COVERAGE CHARTS 3298 Family Rev 4 07 125 8 ...
Page 126: ...3298 HYDRAULIC COVERAGE CHARTS 126 3298 Family Rev 4 07 ...
Page 127: ...SP 3298 HYDRAULIC COVERAGE CHARTS 3298 Family Rev 4 07 127 8 ...
Page 128: ...SP 3298 HYDRAULIC COVERAGE CHARTS 128 3298 Family Rev 4 07 ...
Page 129: ...V 3298 HYDRAULIC COVERAGE CHARTS 3298 Family Rev 4 07 129 8 ...
Page 130: ...V 3298 HYDRAULIC COVERAGE CHARTS 130 3298 Family Rev 4 07 ...
Page 134: ...134 3298 Family Rev 4 07 ...
Page 136: ...IMPELLER TRIM PROCEDURE 136 3298 Family Rev 4 07 Fig III 2 Group S M Fig III 3 Group L ...
Page 142: ...142 3298 Family Rev 4 07 ...