INSPECTIONS
Model 3298 parts must be inspected to the following criteria
before reassembly to ensure pump will run properly. Any
part not meeting required criteria should be replaced.
CASING (100)
1.
Casing (100) should be inspected for excessive wear,
abrasive damage, cut or a loose liner.
VOLUTE INSERT (SP 3298 Only)
1.
Volute insert (100U) should be inspected for excessive
wear, abrasive damage or cut surfaces.
SPIDER (101A)
1.
Spider Bearing should be inspected for cracks, chips,
or scoring.
IMPELLER (101)
1.
Inspect leading and trailing edges of vanes for
erosion damage.
2.
Inspect impeller for cracks and grooves in excess of
.030 in. (.75 mm).
3.
Check for blocked passages.
BACKPLATE (SP 3298 Only)
1.
Backplate (444) should be inspected for excessive wear,
abrasive damage, cut or a loose liner.
INSPECTION LOCATIONS:
*
For M and L Group Sizes Only -
2 x 3-8, 3 x 4-7, 1 x 2-10, 4 x 6-10
BACK WEAR RING (203)
1.
Inspect back wear ring per following table:
Table 9
Diametrical Back Wear Ring Clearances
Size
New
Clearance
in. (mm)
Replace
at
in. (mm)
Wear Ring to
Containment
Shell
Location A
Ref. Fig. 101 /
102
1 x 1½-5
1½ x 2-6
1 x 1
1
2
-6
1 x 1½-7
1 x 1½-8
No Wear Ring No Wear Ring
2 x 3-6
1½ x 3-8
1 x 1
1
2
-8
3 x 4-7
2 x 3-8
0.060/0.066
(1.52/1.68)
0.090
(2.3)
1 x 2-10
1½ x 3-10
2 x 3-10
3 x 4-10H
3 x 4-10G
0.060/0.070
(1.52/1.78)
0.094
(2.4)
4 x 6-10
NOTE: S group sizes 1 x 1
1
2
-6, 1 x 1
1
2
-8, 2 x 3-6 do
not have wear ring (203).
64
3298 Family Rev. 4/07
Fig. 102
Fig. 101
Summary of Contents for Goulds Pumps V 3298
Page 6: ...6 3298 Family Rev 4 07 ...
Page 26: ...26 3298 Family Rev 4 07 ...
Page 32: ...32 3298 Family Rev 4 07 ...
Page 38: ...38 3298 Family Rev 4 07 ...
Page 112: ...112 3298 Family Rev 4 07 ...
Page 115: ...3298 Family Rev 4 07 115 7 ...
Page 116: ...INTERCHANGEABILITY 3298 XS GROUP 116 3298 Family Rev 4 07 ...
Page 117: ...INTERCHANGEABILITY 3298 S GROUP 3298 Family Rev 4 07 117 7 ...
Page 119: ...INTERCHANGEABILITY 3298 L GROUP 3298 Family Rev 4 07 119 7 ...
Page 120: ...INTERCHANGEABILITY SP 3298 S GROUP 120 3298 Family Rev 4 07 ...
Page 121: ...INTERCHANGEABILITY V 3298 S GROUP 3298 Family Rev 4 07 121 7 ...
Page 122: ...INTERCHANGEABILITY V 3298 M GROUP 122 3298 Family Rev 4 07 ...
Page 124: ...124 3298 Family Rev 4 07 ...
Page 125: ...APPENDIX I 3298 HYDRAULIC COVERAGE CHARTS 3298 Family Rev 4 07 125 8 ...
Page 126: ...3298 HYDRAULIC COVERAGE CHARTS 126 3298 Family Rev 4 07 ...
Page 127: ...SP 3298 HYDRAULIC COVERAGE CHARTS 3298 Family Rev 4 07 127 8 ...
Page 128: ...SP 3298 HYDRAULIC COVERAGE CHARTS 128 3298 Family Rev 4 07 ...
Page 129: ...V 3298 HYDRAULIC COVERAGE CHARTS 3298 Family Rev 4 07 129 8 ...
Page 130: ...V 3298 HYDRAULIC COVERAGE CHARTS 130 3298 Family Rev 4 07 ...
Page 134: ...134 3298 Family Rev 4 07 ...
Page 136: ...IMPELLER TRIM PROCEDURE 136 3298 Family Rev 4 07 Fig III 2 Group S M Fig III 3 Group L ...
Page 142: ...142 3298 Family Rev 4 07 ...