PARALLEL ALIGNMENT
A unit is in parallel alignment when indicator P (parallel
indicator) does not vary by more than .002 in. (.05 mm) as
measured at four points 90° apart at operating temperature.
Note the preliminary cold setting criteria,
Table 2
.
Vertical Correction (Top to Bottom)
1.
Zero indicator P at top dead center of coupling
(12 o’clock) half Y (Fig. 19).
2.
Rotate indicator to bottom dead center
(6 o’clock). Observe needle and record reading.
3.
Negative Reading
- Coupling half X is lower than
coupling half Y. Correct by removing shims of
thickness equal to half of the indicator reading under
each driver foot.
Positive Reading - Coupling half X is higher than
coupling half Y. Correct by adding shims of thickness
equal to half of the indicator reading from each driver
foot (Fig. 20).
NOTE: Equal amounts of shims must be added to or
removed from each driver foot. Otherwise the vertical
angular alignment will be affected.
4.
Repeat steps 1 through 3 until indicator P reads within
.002 in. (.05 mm) or less when hot, or per Table 1
when cold.
Horizontal Correction (Side to Side)
1.
Zero indicator P on the left side of coupling half Y,
90° from top dead center (9 o’clock).
2.
Rotate indicators through top dead center to the right
side, 180° from the start. Observe needle and record
reading (3 o’clock).
3.
Negative Reading
- Coupling half Y is to the left of
coupling half X. Correct by sliding driver evenly in the
appropriate direction (Fig. 21).
Positive Reading
- Coupling half Y is to the
right of coupling half X. Correct by sliding driver
evenly in the appropriate direction.
NOTE: Failure to slide motor evenly will affect
horizontal angular correction.
4.
Repeat steps 1 through 3 until indicator P reads .002
in. (.05 mm) or less.
5.
Re-check both horizontal and vertical readings to
ensure adjustment of one did not disturb the other.
Correct as necessary.
COMPLETE ALIGNMENT
A unit is in complete alignment when both indicators A
(angular) and P (parallel) do not vary by more than .002 in.
(.05 mm) as measured at four points 90° apart.
Vertical Correction (Top to Bottom)
1.
Zero indicators A and P at top dead center
(12 o’clock) of coupling half Y.
2.
Rotate indicator to bottom dead center (6 o’clock).
Observe the needles and record the readings.
3.
Make corrections as outlined previously.
Horizontal Correction (Side to Side)
1.
Zero indicators A and P on the left side of coupling
half Y, 90° from top dead center (9 o’clock).
2.
Rotate indicators through top dead center to the right
side, 180° from the start (3 o’clock). Observe the
needle, measure and record the reading.
3.
Make corrections as outlined previously.
4.
Recheck both vertical and horizontal readings to
ensure adjustment of one did not disturb the other.
Correct as necessary.
3298 Family Rev. 4/07
21
3
Fig. 21
Fig. 20
Summary of Contents for Goulds Pumps V 3298
Page 6: ...6 3298 Family Rev 4 07 ...
Page 26: ...26 3298 Family Rev 4 07 ...
Page 32: ...32 3298 Family Rev 4 07 ...
Page 38: ...38 3298 Family Rev 4 07 ...
Page 112: ...112 3298 Family Rev 4 07 ...
Page 115: ...3298 Family Rev 4 07 115 7 ...
Page 116: ...INTERCHANGEABILITY 3298 XS GROUP 116 3298 Family Rev 4 07 ...
Page 117: ...INTERCHANGEABILITY 3298 S GROUP 3298 Family Rev 4 07 117 7 ...
Page 119: ...INTERCHANGEABILITY 3298 L GROUP 3298 Family Rev 4 07 119 7 ...
Page 120: ...INTERCHANGEABILITY SP 3298 S GROUP 120 3298 Family Rev 4 07 ...
Page 121: ...INTERCHANGEABILITY V 3298 S GROUP 3298 Family Rev 4 07 121 7 ...
Page 122: ...INTERCHANGEABILITY V 3298 M GROUP 122 3298 Family Rev 4 07 ...
Page 124: ...124 3298 Family Rev 4 07 ...
Page 125: ...APPENDIX I 3298 HYDRAULIC COVERAGE CHARTS 3298 Family Rev 4 07 125 8 ...
Page 126: ...3298 HYDRAULIC COVERAGE CHARTS 126 3298 Family Rev 4 07 ...
Page 127: ...SP 3298 HYDRAULIC COVERAGE CHARTS 3298 Family Rev 4 07 127 8 ...
Page 128: ...SP 3298 HYDRAULIC COVERAGE CHARTS 128 3298 Family Rev 4 07 ...
Page 129: ...V 3298 HYDRAULIC COVERAGE CHARTS 3298 Family Rev 4 07 129 8 ...
Page 130: ...V 3298 HYDRAULIC COVERAGE CHARTS 130 3298 Family Rev 4 07 ...
Page 134: ...134 3298 Family Rev 4 07 ...
Page 136: ...IMPELLER TRIM PROCEDURE 136 3298 Family Rev 4 07 Fig III 2 Group S M Fig III 3 Group L ...