Original notice - A1.20
47
There are two types of settings to change speed: the internal speed setting to change
the speed by switches on the driver card, and the external speed setting to change the
speed by inputting the analog voltage to CN2#3.
SW5
56
7
8
90 12
3
4
SW1
#1
#2
#3
#4
#5
ON OFF OFF OFF ON
12345
CN2#3
DC
0
〜
10V
IN
SW1
#1
#2
#3
#4
#5
ON
ON OFF OFF ON
Internal speed setting
External speed setting
Set SW1#2 to OFF.
Set SW1#5 and SW5.
1
1
1
2
2
Turn SW1#2 ON.
Input the voltage to CN2#3.
1
2
2
M1
:
Carrier wheel transfer
M2
:
Roller transfer
8-3.
Changing the
transfer speed
V-ribbed pulley
〔
M1:CBK-109 / M2:CB-016
〕
Changing the transfer speed
Changing the transfer speed
■
The speed can be changed even during transfer (when RUN signal is being
input).
8.
Control/Operation
F-RAT-NX75 Technical document
Safety precautions
Advance preparation
Product check
Structures
Installation/Wiring
Control/Operation
Maintenance/Inspection
Tr
oubleshooting
Appendix