Original notice - A1.20
7.
Installation/Wiring
37
CN1
(
Power
)
#2
#1
0V
DC24V
Required for RUN/STOP signals.
The transfer direction can be switched.
・
Outputs 2-pulse signal per rotation of the internal motor.
NPN open collector output.
・
Attach protection resistance so that the output is 25 mA or less.
・
3URWHFWLRQUHVLVWDQFHRIȍLVLQFOXGHGLQVLGHGULYHUFDUGV
Detects MDR errors, and outputs.
Settings for normal output and error output can be specified using ON/OFF on DIP-SW1#4.
・
Open collector output.
Attach protection resistance so that the output is 25 mA or less.
・
3URWHFWLRQUHVLVWDQFHRIȍLVLQFOXGHGLQVLGHGULYHUFDUGV
・
If output is connected to inductive load (Ex. Relay coil , solenoid ,
actuator , etc . ), make sure to protect output from Back voltage with a
free-wheeling diode.
The transfer speed can be set by the voltage input of 0 - 10V.
Functions
Detailed descriptions
CN2
(
Control
)
#5
#4
#3
#2
#1
Output
Output
Analog
input
Input
Input
Motor pulse
output
Error signal
output
MDR external
speed setting
MDR rotation
direction switching
MDR RUN/STOP
7mm
DC 24V
(
AWG:28
〜
20
)
DC 0V
7mm
0.08
〜
0.5mm
2
0.50
〜
1.5mm
2
(
AWG:20
〜
14
)
Power connector
(CN1)
Control connector
(CN2)
}
( )
OUT
CB-016BN7:
0V
CB-016BP7:
24V
( )
CB-016BN7:
0V
CB-016BP7:
24V
0V
0-10V IN
DC24V
CN2
CN1
}
IN
24V
1.RUN
3.V-IN
2.DIR
4.ERR
5.PLS
0V
2
1
5
4
3
2
1
■
Connector descriptions
〔
CB-016
〕
M2
:
For roller transfer
CB-016
Wiring for CB-016
Wiring for CB-016
Power connector (CN1)
1
Connect the 24V DC and 0V DC cables to CN1
(2 pin).
Connect each cable to CN2 (5 pin).
*
Refer to the above, and perform wiring according to operation.
Connect the power connector (CN1), control
connector (CN2), and M2 MDR connector to
driver cards.
■
Do not connect multiple power cables to one
pole. Failure to follow this could result in
electric shock, short circuit, and/or damage
due to the capacity of connectors being
exceeded. (Connector capacity: 10 A)
■
Do not connect the 24V DC and 0V DC cables
incorrectly.
■
Do not connect cables when connectors are
plugged in.
■
Use the same voltage to be input to CN2#1
(MDR RUN/STOP) and CN2#2 (MDR rotation
direction) as the power supply voltage.
(Connector capacity: 4A)
Control connector (CN2)
2
MDR connector
〔
M2
〕
Connecting to driver cards
3
CBK
F-RAT-NX75 Technical document
Safety precautions
Advance preparation
Product check
Structures
Installation/Wiring
Control/Operation
Maintenance/Inspection
Tr
oubleshooting
Appendix
For more details on CB-016, please download the driver card user manual from
our web page.
Home > Documents > Technicla documentation
http://itoh-denki.com/en/documents/technical-documentation/circuit-boards
ITOH DENKI
CB-016