Original notice - A1.20
17
4.
Advance preparation
MDR extension cable
(option)
Stay
(option)
Wiring materials
Necessary for wiring of power and signal cables, branch connectors, driver cards,
controllers, such as sensors or PLCs, and power supply.
60
L
±5
37
(Male side)
(Female side)
Model
10P extension cable length
ACE-CBM-A0600
ACE-CBM-A1200
L= 600mm
L=1200mm
Model
12P extension cable length
ACE-CBM-G0600
ACE-CBM-G1200
L= 600mm
L=1200mm
Necessary when the installing location of the F-RAT main unit is far from that of the
driver cards.
■
CBK-109
:
12P extension cable
■
CB-016
/
HBM-201
:
10P extension cable
〈
Available wire diameter for driver card connectors
〉
Power connector
Driver card
Connector
Control connector
CBK-109
CB-016
/
HBM-201
0.5
〜
1.5
m㎡(
AWG
:
20
〜
14
)
0.08
〜
0.5
m㎡(
AWG
:
28
〜
20
)
0.8
〜
1.5
m㎡(
AWG
:
18
〜
14
)
60
L
±5
(Male side)
(Female side)
37
37.5
32.5
MDR extension cable (option)
Size
6040 / 7540 / 9040
6050 / 7550 / 9050
370
(mm)
470
L
X
400
500
6060 / 7560 / 9060
6070 / 7570 / 9070
570
670
600
700
6080 / 7580 / 9080
770
800
*
For X dimensions (between frames) other than those mentioned above, contact us.
L
19.8
48
21.3
35
X (Between frames)
4.5
For hex. bolt M8/using spring washer
For hex. bolt M8
Using plain water/
spring washer
2-
∅
9
2-M8
■
Use extension cables of 1200 mm or less.
■
Do not extend cables by connecting multiple extension cables.
■
To select the current capacity of wiring materials, secure a high safety margin
based on the current value in the equipment to be used.
■
Longer wiring between the power supply unit and driver cards/controllers could
cause the voltage to decrease, resulting in malfunction and/or damage.
F-RAT-NX75 Technical document