Regency
®
Model 4724 Control Expander Installation Manual (P/N 150596-02, Rev. A)
Revised 8/98
46
Table 14: Status and Port Addresses
Name
Address.Point
Operations
Functions
AARMED[1-8]
@$BO-7.0
GET1
Area armed
ACCAREA
@$616.
GET1
Last group of areas granted
door access
ACHIME[1-8]
@$B0-7.3
GET1
Area chime activated
ACODE2[1-8]
@$BO-7.4
GET1
Area CODE2 activated
AENTRY[1-8]
@$B8-F.1
GET1
Area entry activated
AEXIT[1-8]
@$B8-F.0
GET1
Area exit activated
AINST[1-8]
@$B0-7.2
GET1
Area instant activated
ALMAREA.0-.7
@$79.0-7
GET1, GET8
Area in alarm
AREADY[1-8]
@$BO-7.1
GET1
Area zones ready
ABYPASS[1-8]
@$BO-7.5
GET1
Area zones bypassed
ATROUBLE[1-8]
@$BO-7.6
GET1
Area zone trouble
AUDALM
@$27.7
GET1
Audible alarm
AUDAREA.0-.7
@$78.0-7
GET1, GET8
Area audible alarm
AUXALM
@$26.1
GET1
Aux. alarm activated
AUXRLY.0-.7
@$6D.0-7
GET1, GET8
4150 relay status
AZONES[1-18].0-.7
@$40a-$41B.0-7
GET1, GET8
Armed zones
BYPASS
@$25.5
GET1
Global zones bypassed
CLGRP
@$1A.5
GET1
Close time window group
DACT
@$68.2
GET1
Dialer active
DOOR80.0-.7
@$18.0-7
GET1, GET8
Toggle with 1-8 door
DOOROPEN [0-15]
@$491-$4A0.2
GET1
Touchpad door open
DOORRLY [0-15]
@$491.7 -4A0.7
GET1,PUT1
4660C/4433/4420 touchpad relay status
DOORSUPR[0-15]
@$491-$4A0.1
GET1
Touchpad door trouble
DURESS
@$26.6
GET1
Duress alarm
EMER
@$2A.1
GET1
Emergency alarm
EXEC
@$3F.0
GET1
IF/THEN control bit
EXTBELL
@$29.3
GET1
External bell active
FIRE
@$28.0
GET1
Fire alarm
HLDAY
@$2A.0
GET1
Holiday
HZNC[1-18].0-.7
@$2FC-$30D.0-7
GET1, GET8
Zone high threshold trip
ICALL
@$617.
GET8
Station # for intercom call
ICOM
@$6C.0
GET1
Intercom active
INTBELL
@$29.2
GET1
Internal bell active
INTRU
@$28.2
GET1
Intrusion alarm
IRDY
@$24.0
GET1
Zones all ready