Regency
®
Model 4724 Control Expander Installation Manual (P/N 150596-02, Rev. A)
Revised 8/98
25
AUTO OPEN:NO
Selecting this option causes the system to disarm itself automatically, if the panel is not dis-
armed at the end of any time window in the Auto Open Window Group (OP WIN GRP).
NOTE
For both AUTO CLOSE and AUTO OPEN, there must be at least a one-minute break between
the end of one Auto Close (Open) Time Window and the beginning of the next one. Otherwise,
the system will not arm (disarm), until the end of the second time window.
If you are using auto open/close in a multi-area system, see Sections 5.1 and 11.1 of this man-
ual for more information.
Example:
Suppose you select Window Group 1, to which you've assigned the time windows shown
below, for OP WIN GRP
Time Window #3
—
Monday-Friday, 7:00-8:00 AM
Time Window #4
—
Monday-Friday, 1:00-2:00 PM
Time Window #5
—
Saturday, 9:00-10:00 AM
Time Window #6
—
Saturday, 10:00-11:00 AM
On Monday through Friday, if no one has disarmed the system by 8:00 AM, the system
will disarm automatically at 8:00 AM (end of Time Window #3). If someone arms the sys-
tem later in the morning (before leaving the office for lunch, for example) and no one dis-
arms it by 2:00 PM, the system will disarm automatically at 2:00 PM (end of Time
Window #4).
Time Window #5) the system will NOT disarm automatically, because another time win-
dow (Time Window #6) in the open window group follows immediately. If the system has
not been disarmed manually by 11:00 AM (end of Time Window #6), it will disarm auto-
matically at that time.
AUTO NO FRC:NO (4)
When selected Auto Close will cause alarms on any Not Ready Zones.
OP WIN GRP:32
This option makes it possible to have more than one opening period in a day using Revision A-
G software. See Menu 14 for Revision H information.
NOTE
Revision A-G: Select the window group during which the system can be disarmed. At the end of
this time period, the system will automatically disarm (open)
1) if it has not already been disarmed by a user and
2) if AUTO OPEN has been enabled (see Section 5.4 of this manual).
Revision H: The option is retained here for programmable I/O compatibility. This option is not
used on Revision H software. It is replaced by a similar option for each area in Menu 14. OP
WIN GRP controls bit OPGRP in the programmable I/O. CL WIN GRP controls CLGRP.