Regency
®
Model 4724 Control Expander Installation Manual (P/N 150596-02, Rev. A)
Revised 8/98
23
REP EXC O/C:NO (Report Openings/Closings at
“
Exceptional
”
Times)
When this option is selected, the system will report openings and closings only if they occur
outside of specified time windows.
REP OT/CT:NO
Selecting this option causes the system to send an Open Trouble Report or Close Trouble
Report to the central station if the user fails to arm or disarm during a specified time window.
REP DG:NO (Report Door Access Granted)
This option causes the system to send a report indicating that the door was accessed using a
valid code number. The event is also printed.
REP BYPS ID:NO
When this option is selected, the user ID will be reported when anyone bypasses a zone. This
will only occur if the option BYPASS CODE has been selected. (Currently, the Model 9000
does not support this feature.)
AUTO DUMP CS:NO
Select
NO
. This option is not available. The 5540 Downloading Software must be used to
dump event memory to the central station (see Section 6 and Section 9 of this manual).
SPLIT BYPS:NO
Codes 2 through 144 can bypass only their corresponding zones. (Code 2 can bypass only
Zone 2; Code 3 can bypass only Zone 3, etc.)
NOTE
Exception: Code 0 and Code 1 can bypass all zones regardless of how this option is pro-
grammed.
CHIME PZT:NO
When this option is selected, the chime tone will be heard at all touchpads assigned to the same
area as the chime zone.
NOTE
If this option is not selected, the chime will be heard only at the speakers.
MAX SKEY ID:1 (Maximum Supervised Touchpad ID)
For this option, enter the highest touchpad ID number that will be supervised. Touchpads with
higher numbers can be used, but they will not display area entry/exit or LED information. You
must give your supervised touchpads ID numbers in sequential order starting at 1. For more
information on this topic, please see the Model 4720 Installation Manual (P/N 150476).
NOTE
A. Touchpads must be supervised to be fully functional.
B. Stations with higher ID numbers can still be used, but will not be supervised.
DISPLAY RATE:3s
Select a speed in the range of 1-4 seconds. This option controls the rate at which all displays
are updated.
FAST RESTORE:NO
When this option is selected, the system reports restores as soon as the alarm is restored,
instead of waiting for the shutdown time.