Installing the System
4
Setting the Optional Energy
Saver Module (ESM), Hardwire
Input Module (HIM) and Hard-
wire Output Module (HOM)
Unit Number DIP Switches
All devices connected to the panel’s SuperBus hard-
wire bus have individual unit numbers assigned. Al-
phanumeric touchpad unit numbers are changed in
software during programming. The Energy Saver
Module (ESM), Hardware Input Module (HIM), and
Hardware Output Module (HOM) are set with DIP
switches inside the modules. For unit number setting
details, refer to the installation instructions provided
with the bus device.
Duplicated unit numbers will prevent those bus devic-
es from operating. Refer to table D.3 in appendix D
for recommended SuperBus device unit number set-
tings.
To set your ESM, HIM, or HOM unit number:
1. Set the module unit number DIP switches to the
desired unit number as shown the figure 4 per the
recommendations in table D.3 in appendix D.
The unit number is set to 0 (zero) at the factory
and is OK for most single touchpad and single
ESM, HIM, or HOM module applications. Make
sure that no bus devices (including hardwire
touchpads) share the same unit number (device
address).
Caution
The alphanumeric touchpad unit number defaults to 1 (one).
Do not set the ESM, HIM, or HOM unit number to 1. Doing
so will prevent the touchpad from functioning.
2. Turn the control panel power switch off and then
back on so the bus module can read the unit num-
ber switch settings into its memory.
3. Enter and exit PROGRAM MODE by switching
the panel PROGRAM/RUN switch to PRO-
GRAM and back to RUN so the panel can
“learn” the new bus device unit numbers.
If the alphanumeric touchpad (or other SuperBus de-
vice) no longer seems to function, check if the same
unit number assigned is to more than one device. Su-
perBus devices cannot share the same unit number.
Figure 4 Setting the ESM, HIM, or HOM Unit Num-
ber Dip Switches
Note
All SuperBus devices such as Energy Saver, Hardwire In-
put, and Hardwire Output Modules and alphanumeric touch-
pads must have unique unit number (address) settings.
Devices with the same (conflicting) address will not function
properly. Module address switches 1–5 must remain down
(off).
Installing the Backup Battery
The panel uses one rechargeable, sealed 12V lead-
acid backup battery.
Note
Both standard (60-681) 12V, 4AH and heavy duty (60-680)
12V, 6.5AH backup batteries are available. Always replace
with the same battery type and size.
8557G32A.DS4
UNIT NUMBER 0
UNIT NUMBER 1
UNIT NUMBER 2
UNIT NUMBER 3
UNIT NUMBER 4
UNIT NUMBER 5
UNIT NUMBER 6
UNIT NUMBER 7
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
Summary of Contents for ITI UltraGard
Page 62: ...Appendix F UL Requirements 58...