Programming the Panel
17
Programming Touchpad Key
Beeps
The touchpad key beeps option determines whether
key-press sounds are heard from a specific touchpad.
The following procedure must be done at the specific
touchpad you want changed.
The touchpad key beeps default is Y (yes—keys beep
when pressed).
To change alphanumeric touchpad key beeps:
1. In PROGRAM MODE, press BYPASS until
TOUCHPAD OPTIONS is displayed.
2. Press COMMAND. Display reads UNIT NUM-
BER.
3. Press BYPASS or STATUS until the display
reads KEYBEEPS N (no) or Y (yes).
4. Press COMMAND to toggle Y or N.
5. Press FIRE to exit.
Note
The key beeps option does not actually change until the
panel RUN/PROGRAM switch is changed from PROGRAM
to RUN.
Programming the Interrogator
200 Audio Verification Module
Mode, Time-out, and Access
Code
The optional Interrogator 200 Audio Verification
Module* (AVM) allows for two-way voice communi-
cation with the monitoring station in the event of an
alarm. The AVM mode, time-out, and access code
need to be programmed. The default AVM mode is 03
(instant).
* Not intended for use with UL-listed systems.
To change the Audio Verification Module mode of
operation:
1. In PROGRAM MODE, press BYPASS until
AVM MODE
is displayed.
2. Press COMMAND to display AVM MODE -
[present AVM mode number].
3. Enter the desired two-digit AVM mode number:
01 - One-ring
02 - One-ring Silent
03 - Instant
09 - One-ring Fire Siren Shutdown
10 - One-ring Silent Fire Siren Shutdown
11 - Instant Fire Siren Shutdown
4. Press COMMAND. AVM MODE - [new mode
number] is displayed.
5. Press FIRE to exit.
The AVM time-out determines how long the AVM
will wait without hearing a command before hanging
up. The default AVM time-out is 90 seconds.
To change the Audio Verification Module time-
out:
1. In PROGRAM MODE, press BYPASS until
AVM TIME-OUT
is displayed.
2. Press COMMAND to display AVM TIME-OUT
- [present time-out in seconds].
3. Enter the desired three digit AVM time-out (030
to 300 seconds in 2-second increments).
4. Press COMMAND. AVM TIME-OUT - [new
time-out] is displayed.
5. Press FIRE to exit.
The AVM access code helps prevent unauthorized lis-
ten-in/talk-back audio sessions. The default AVM ac-
cess code is blank (****).
To program the Audio Verification Module access
code:
1. In PROGRAM MODE, press BYPASS until
AVM CODE
is displayed.
2. Press COMMAND to display AVM CODE -
[present access code].
3. Enter the desired four-digit AVM access code
(0001 to 9998) or press POLICE to clear the dis-
played code.
Note
See table D.6 in appendix D for code number defaults and
restrictions.
4. Press COMMAND. AVM CODE - [new access
code] is displayed.
5. Press FIRE to exit.