![ITI ITI UltraGard Installation Instructions Manual Download Page 42](http://html1.mh-extra.com/html/iti/iti-ultragard/iti-ultragard_installation-instructions-manual_2095634042.webp)
Appendix C: Programming Tables
38
20
Delayed
Interior
PIR motion sensors that initiate a delay
before going into alarm.
*
Police
Standard
√
√
3
21
Local
Instant
Interior
24-hour local alarm zone protecting
anything that opens and closes.
Police
Instant
√
√
1, 2, 3
22
Local
Delayed
Interior
Same as group 21, plus activation ini-
tiates a delay before going into alarm.
Police
Standard
√
√
1, 2, 3
23
Local
Instant
Auxiliary
24-hour local alarm zone protecting
anything that opens and closes. ‡
Auxiliary
Instant
√
√
1, 2, 3
24
Local
Instant
Auxiliary
24-hour local alarm zone protecting
anything that opens and closes. Sirens
shut off at restoral.
*
Auxiliary
Instant
√
√
1, 2, 3
25
Local
Special
Chime
Notify the user when a door is opened.
Sounds emit from a local annunciator.
*
Special
Chime
Instant
√
1, 2, 3
26
Fire
24-hour fire, rate-of-rise heat, and
smoke sensors.
§
Fire
Instant
√
√
√
1, 2, 3
27
Output
Module
Hardwire Output Module (HOM) lamp
control or other customer feature.
‡
Silent
Instant
√
√
1, 2, 3
28
Output
Module
HOM, PIR motion sensor, sound sen-
sor, or pressure mat.
‡
Silent
Instant
√
1, 2, 3
29
Auxiliary
Freeze sensor.
Auxiliary
Instant
√
√
1, 2, 3
32
Output
Module
HOM, PIR motion sensor, sound sen-
sor, or pressure mat.
‡
Silent
Instant
1, 2, 3
Note: Check marks (
√
) represent characteristics present in a group.
*
This group is not certified as a primary protection circuit for UL-listed systems and is for supplementary use only.
†
Sounds instant police siren if two or more sensors are tripped within 4 minutes. Otherwise sensors are followers to delayed
sensors. If central station feature 15 (Alarm Verification) is on, group 18 functions like group 17.
‡
This group has not been investigated by UL.
§
This group is required for UL-listed residential fire alarm applications.
Table C.1 Sensor Group Characteristics (Continued)
No.
Name
Application
Alarm
Delay
Restoral
Supervisory
CS
Report
Chime
Active
Levels
Summary of Contents for ITI UltraGard
Page 62: ...Appendix F UL Requirements 58...