01 - 10 - 2004
Console user manual
27
D.3
Generic messages for Hi Drive code y
These messages provide extra information in certain special situations:
Generic message 1 HD code 1
The max number of loom start-ups per minute at
continuous running has been exceeded. The green and
white lamps start flashing alternatively.
Generic message 1 HD code 2
More than 6° have been covered without release during
manual release; likely causes:
- incorrect coupling gap
- mechanical coupling malfunction
- auxiliary encoder malfunction
Generic message 1 HD code 3 Release timeout during manual release
Generic message 1 HD code 4 Start-up at continuous running interrupted due to oil pump
or min pressure switch, first control
Generic message 1 HD code 5 Start-up at continuous running interrupted because
enabling relay KD2 is open
Generic message 1 HD code 6 Start-up at continuous running interrupted due to oil pump
or min pressure switch, second control
Generic message 1 HD code 7 Start-up at continuous running interrupted due to
electromechanical brake safety check
Generic message 1 HD code 8 Incorrect start-up at continuous running
Generic message 1 HD code 9 Start-up at continuous running interrupted due to
unaccepted DMM status
Generic message 1 HD code 10 Start-up at continuous running interrupted due to let-offs
and/or take-up
Generic message 1 HD code 11 Start-up at continuous running interrupted due to splitz or
IES