Chapter 4 SYSTEM SETTING MENU
4-20
IL-EMZ Service Manual
6. By operation of No. 3,
Enter the Threshold Preset
value
at numeric keys, and press the [Label sensor
DPM] field.
Threshold Preset value
A
2/3
1/2
A
is the value between label detection part
and label gap detection part.
Label detection part is the highest value.
Label gap detection part is the lowest value.
Preset value is between one half of
A
, and
2/3.
Summary of Contents for IL-EMZ
Page 8: ...vi IL EMZ Service Manual memo ...
Page 13: ...Chapter 1 INSTALLATION IL EMZ Service Manual 1 5 1 3 OUTER DIMENSIONS Unit mm ...
Page 18: ...Chapter 1 INSTALLATION 1 10 IL EMZ Service Manual memo ...
Page 52: ...Chapter 2 SETUP MENU 2 34 IL EMZ Service Manual ...
Page 80: ...Chapter 3 TEST MENU 3 28 IL EMZ Service Manual memo ...
Page 85: ...Chapter 4 SYSTEM SETTING MENU IL EMZ Service Manual 4 5 ...
Page 89: ...Chapter 4 SYSTEM SETTING MENU IL EMZ Service Manual 4 9 ...
Page 94: ...Chapter 4 SYSTEM SETTING MENU 4 14 IL EMZ Service Manual ...
Page 122: ...Chapter 6 ELECTRIC ASSEMBLY 6 2 IL EMZ Service Manual 6 1 ELECTRIC BLOCK DIAGRAM ...
Page 145: ......