6. By operation of No. 3 and No.5, Please adjust the
output of label gap to 200 - 240.
7. By operation of No. 4, Enter the Threshold Preset
value at numeric keys, and press the [Label sensor
DPM] field.
XXX
Threshold Preset value
A
2/3
1/2
A
is the value between label detection part
and label gap detection part.
Label detection part is the highest value.
Label gap detection part is the lowest value.
Preset value is between one half of
A
, and
2/3.