Chapter 3 TEST MENU
IL-EMZ Service Manual
3-17
Please adjust the output of label gap to 200 - 240.
Check whether the levels of the label portion are less
than about 40 ranges.
Lower the gain, if level is 40 or more.
Then, the level of the gap also becomes small.
Adjustment is completion if the gap level is about 100 or
more, between label gap level from label portion level.
It sets threshold Mode,In not fulfilling the
above-mentioned conditions,and case of 60 or more
output at Label portion.
Adjustment of Threshold Detection mode can be
performed in
system setting mode
.
200
240
Label portion
Level<40
Level>100