DcSetup programme
Positioning module UVE8112, IMD10
Velocity dialogue box
The maximum speed is the limitation for the speed of all motion functions with a ramp (profile velocity
mode, profile position mode). I.e. the speed cannot become greater than this value, even if a different
parameter (e.g. Target velocity 60FFh) contains a higher value.
the mode of operation “Velocity controller with analogue input”, this value corresponds to the
In
maximum achievable speed (-10 V …-+10 V –max. velocity ... +maximum speed). See “Operation
Mode ”on page 44.
The determination of this parameter can be carried out automatically. Here, it is, however, necessary
to define a motion sector, since the axis might cover a long way during the acceleration to the
maximum speed and the subsequent braking and may not drive into the mechanical stop.
See Acceleration dialogue box on page 57.
In order to determine this motion area, at least one limit point has to be set in which the axis is driven
to the corresponding spot via a Teach dialogue. In the beginning, both limit points contain the actual
position.
The acceleration is by default set to 20 % of the maximum acceleration in order to go easy on the
mechanical parts, if e.g. the motion sector becomes too small.
The maximum speed is determined internally and then limited to 95 %, in order to dispose of a good
reserve for the regulation.
58
Summary of Contents for IMD1
Page 1: ...DC servo positioning module with CanOpen interface UVE8112 IMD10 www isel com ...
Page 66: ...DcSetup programme Positioning module UVE8112 IMD10 66 ...
Page 113: ...Positioning module UVE8112 IMD10 Appendix 113 Appendix UVE8112 package dimensions ...
Page 114: ...Appendix Positioning module UVE8112 IMD10 114 IMD10 package dimensions ...