DcSetup programme
Positioning module UVE8112, IMD10
<OK>
Changes are applied. The dialogue box is closed. A permanent
storing does not take place. The permanent storing of data can be
realised via the “Object Directory dialogue box” of the
Settings\Object Directory main menu.
<CANCEL> Changes are not applied; the parameters are not saved.
<APPLY> The set of parameters is only transferred to the module. A
permanent storing is only carried out automatically, if the default
password “ISEL” is in use. Otherwise it is not carried out. The
permanent storing of data can always be realised via the <OK>
button or via the “Object Directory dialogue box” of the
Settings\Object Directory main menu.
The commissioning via this option is reasonable, if one wants to make a quick change or detail
improvements. In cases in which the drive module can move because of its own weight, even if the
system is dead, a new commissioning shall also be carried out with the help of this option. For this,
the parameters of the current, velocity or position controller have at first to be set to default values.
The control is thus activated. On the basis of these default values, all other parameters can be
determined. Here, in the beginning, it is hardly possible to carry out the commissioning via the “Step-
by-step commissioning” option due to the inactive control.
42
Summary of Contents for IMD1
Page 1: ...DC servo positioning module with CanOpen interface UVE8112 IMD10 www isel com ...
Page 66: ...DcSetup programme Positioning module UVE8112 IMD10 66 ...
Page 113: ...Positioning module UVE8112 IMD10 Appendix 113 Appendix UVE8112 package dimensions ...
Page 114: ...Appendix Positioning module UVE8112 IMD10 114 IMD10 package dimensions ...