background image

page 5

4.  

I

NITIAL POWER-UP, ADDING MASTER KEYS BY RESET BUTTON

Initial power-up sequence (No keys in lock's memory)
-

 

Connect the reader module to the lock module by a supplied cable.

-

 

Insert four AA batteries. 

-

 

Swipe

 the reader by any EM

-

Marine key.

-

 

The controller issues audible and visual signals.

-

 

Device is ready for operation. 

  Note: For consistent reader operation, keys with label diameter 15…35 mm are recommended.

To add a Master key, perform the following steps: 
-

 

Disconnect the power (take out one of the batteries or use the external power supply switch, per 

  Fig. 10);
-

 

Push and hold the RESET button with a sharp tool (hairpin, toothpick, straightened paper clip 

  etc.)
-

 

Connect the power (re-insert the battery, or use the external power supply switch again, per Fig. 

  10), and only after that release the RESET button;
-

 

Within 5 s after this, push and hold RESET button again;

-

 

Swipe

 up to 4 keys to promote to Master one by one  still

 

holding RESET down;

-

 

Release RESET button. In 6 s, both audible and visual signals will confirm exit from the Add 

  Master Key mode.

5.  SELECTING AND SETTING OPERATIONAL MODE BY RESET BUTTON

Note:

 

Cannot select operational mode without a Master key.

The lock supports four 

pre-customised

 operational modes:

  -

 

Gym mode

: allows not to tie up the key to the lock. The user chooses which of the available 

    lockers to use.

  -

 

Logic  mode

:  allows 

record

ing  the  used  locker  number  and  battery  level  into  the  key 

(bracelet). Very convenient when the user

 

forgets which locker he used.

 

Allows not to tie up the key 

to the lock. The user will decide which of the free lockers to use. Works only with Lock Manager 
software.

  -

 

General mode

:

 traditional lock controller operation: only the keys 

record

ed in lock's database 

can open the locker;

  -

 

Safe Deposit Box mode

:

 safe deposit box mode emulation. To open the lock, all the keys in 

lock's database need to be presented to the lock, one after another.

In addition to the above modes you can order your own 

Custom mode

, which will be designed 

according to your needs.

At factory

 settings

Gym mode

 is pre-selected by default. It is activated straight after the Master 

key(s) have been added. To select a different operational mode, follow these steps:
-

 

Disconnect the power (take out one of the batteries or use the external power supply switch, as 

per Fig. 10);
-

 

Press and hold the RESET button with a sharp tool.

-

 

Connect the power (reinsert the battery, or use the external power supply switch, as per Fig. 10), 

and only after that release the RESET button;
-  Press the RESET button shortly (once). The lock issues audible and visual signals 

twice

. The 

lock is now in Logic Mode;
-  Press

 

the

 

RESET

 

button

 

shortly (once). The lock issues audible and visual signals 

three times

The lock is now in General Mode;
-  Press the

 

RESET

 

button

 

shortly (once). The lock issues audible and visual signals 

four times

The lock is now in Safe Deposit Box Mode.

Z-

395

 EHT

www.ironlogic.

me

Summary of Contents for Z-395 EHT

Page 1: ...erized logging and lock setup Only works with Lock Manager software General Mode a typical lock controller operation only the key s stored in the lock s memory maximum 24 can open that lock Safe Deposit Box Mode the lock emulates safe deposit box operation To open the lock all the keys in controller database max 26 must be swipe to it one after another Custom Mode you can design your own custom op...

Page 2: ...rotection against bracelet cloning Locks setup and further use without a PC Note Logic Mode requires special Atmel T5557 keys and Lock Manager software 2 SPECIFICATIONS Working Frequency 125 kHz Keys standards EM Marine HID ProxCard II Atmel T5557 Maximum number of keys Normal 26 Master 4 NVRAM to store settings Present Reading distance 2 4 cm Standby consumption current 30 mkA Audio visual status...

Page 3: ...he locker s wall see Fig 3 4 To mark the hole positions use template from Fig 13 Fig 3 Fig 4 Self tapping Screw 3 5х15 locker s wall Self tapping Screw 3 5х25 push bolt unit Fig 2 A the calculated size depends on thickness of the locker s wall A Connect cable to lock s PCB Note Check that cable socket is firmly connected with lock s PCB socket Install the locking module according to Fig 2 Batterie...

Page 4: ...page 4 Z 395 EHT www ironlogic me How to install the Z 395 EHT lock properly Top view View from inside the door Lock s latch push bolt unit push bolt unit Lock ...

Page 5: ...ws recording the used locker number and battery level into the key bracelet Very convenient when the user forgets which locker he used Allows not to tie up the key to the lock The user will decide which of the free lockers to use Works only with Lock Manager software General mode traditional lock controller operation only the keys recorded in lock s database can open the locker Safe Deposit Box mo...

Page 6: ...s and the LED flashes green The key is erased from lock s memory the latch is withdrawn inside the lock The door is now open lock is ready to restart the cycle from the beginning Legend beep once multiple beeps G Green LED R Red LED blink blinking page 6 Z 395 EHT www ironlogic me Action Sound LED Latch What for Default state None None OUT if a Normal key is in memory Otherwise IN Waiting for Norm...

Page 7: ...er then a beep will sound green LED will flash the key will be erased from the lock s memory the latch will be draw inside the lock The door is now open lock is ready to restart the cycle from the beginning page 7 Z 395 EHT www ironlogic me Action Sound LED Latch What for Default state None None OUT if a locker is occupied otherwise IN Waiting for Normal key assignment Swipe a key G OUT Locker num...

Page 8: ...Master key 1st time R blink IN Entering Edit Normal Keys mode Swipe Master key 2nd time R blink OUT Entering Edit Normal Keys mode Swipe Master key 3rd time for 6 s R IN Entering Edit Normal Keys mode Swipe 1st 2nd 3rd Max 26th keys G IN Recording Normal Key into the controller Swipe Master key R blink OUT Exiting Add Normal Keys mode After 5 s R blink OUT Erase All Normal Keys Default state None ...

Page 9: ...Master key 1st time R blink IN Entering Edit Normal Keys mode Swipe Master key 2nd time R blink OUT Entering Edit Normal Keys mode Swipe Master key 3rd time for 6 s R IN Entering Edit Normal Keys mode Swipe 1st 2nd 3rd Max 24th keys G IN Storing Normal Key into the controller Swipe Master key R blink OUT Exiting Add Normal Keys mode After 10 s R blink OUT Erase All Normal Keys Default state None N...

Page 10: ...ns for Lock s Manager software and RF 1996 adapter can be found on the ironlogic me website 10 ERASING OF ALL MASTER KEYS This function erases all Master keys from lock s database leaving only the Normal keys intact Also cancels the currently selected operating mode To erase all Master keys please perform the following steps a Disconnect the power remove one battery or use the switch on external p...

Page 11: ...ced and the lock lacks energy to open the locker please use external power module power the lock via the connector present on the reader and swipe the lock with the key see Fig 10 Batteries are fully discharged If on Normal key swipe the LED is not flashing AND the lock s latch doesn t pop out it means that lock s batteries are fully discharged In Logic mode the lock records the current battery ch...

Page 12: ... portable computer and subsequent bracelets programming 16 OPERATING CONDITIONS Ambient temperature 5 40 C Humidity 98 at 25 C When operating under non recommended conditions device parameters can deviate from specified values 17 LIMITED WARRANTY This Device is covered by limited warranty for 24 months since the purchase date The warranty becomes void if this Manual s guidelines are not followed t...

Page 13: ...iga Latvia E mail info ironlogic lv headstaff ironlogic lv Phone 37166181894 37124422922 www ironlogic me The symbol of crossed throught waste bin on wheels means that the product must be disposed of at f separate collection point This also applies to the product and all accessories marked with this symbol Products labeled as such must not be disposed of with normal household waste but should be t...

Page 14: ...ut for Z 395 EHT installation onto a wooden chipboard locker Locker s wall 47 35 mm Locker s door Fig 13 A the size is calculated depending on locker chipboard wall thickness A Z 395 EHT www ironlogic me page 14 ...

Reviews: