13. BATTERY DISCHARGE INDICATION AND REPLACEMENT
With 1,500 mAh alkaline batteries, the lock is guaranteed to open at least 10,000 times, or
to work 2.5 years in stand-by mode.
The lock controls the battery charge and informs the users that batteries need to be
replaced.
- Batteries need replacing.
If on Normal key
swipe
, the LED is not flashing, but the lock is still working it means that
lock's batteries are almost totally discharged and need replacing. If the batteries could not
be timely replaced and the lock lacks energy to open the locker, please use external power
module (power the lock via the connector present on the reader) and
swipe
the lock with
the key (see Fig. 10)
- Batteries are fully discharged.
If on Normal key
swipe
, the LED is not flashing AND the lock's latch doesn't pop out it
means that lock's batteries are fully discharged.
In Logic mode, the lock
records
the current battery charge level into the token, on each
lock opening.
- Batteries
replacement.
The lock's electronics include NVRAM for lock settings and keys, so they are not lost after
batteries replacement. To replace the lock's batteries, please see Fig. 11.
Z-
395
EHT
www.ironlogic.
me
Fig
.
11
Fig
.10
External
power
module
OFF-ON