9.  SAFE DEPOSIT BOX MODE

Note: Cannot select an operational mode without a Master key.
Rules of operations for 

Safe

 

Deposit Box mode

.

1.  The latch is always released (OUT), if the database is not empty;
2.  Opening the lock is possible by 

swip

ing ALL the keys to the reader, one after another.

3.  After all keys have been presented, a beep sounds and the LED flashes

 

green, the lock's 

 

latch is withdrawn for 3 s and then is popped back out. If the door was locked, it's opened 

 

by a lock's push bolt.

4.  If a key not present in memory is 

swipe

d, a beep sounds and the LED flashes

 

red.

Z-

395

 EHT

www.ironlogic.

me

Action 

Sound 

LED 

Latch 

What for 

Add Normal Keys

 

Default state 

None 

None 

OUT 

Waiting for Normal key recording 

Swipe Master key 1

st

 time 

 

R blink 

IN 

Entering Edit Normal Keys mode 

Swipe Master key 2

nd

 time 

 

R blink 

OUT 

Entering Edit Normal Keys mode 

Swipe Master key 3

rd

 time 

for 6 s 

 

IN 

Entering Edit Normal Keys mode 

Swipe 1

st

, 2

nd

, 3

rd

, …, Max 

(24

th

) keys 

 

IN 

Storing Normal Key into the controller 

Swipe Master key 

 

R blink 

OUT 

Exiting Add Normal Keys mode 

After 10 s 

 

R blink 

OUT 

Erase All Normal Keys

 

Default state 

None 

None 

OUT 

Waiting for Normal key written 

Swipe Master key 1

st

 time 

 

R blink 

IN 

Entering Edit Normal Keys mode 

Swipe Master key 2

nd

 time 

 

R blink 

OUT 

Entering Edit Normal Keys mode 

Swipe Master key 3

rd

 time 

for 6 s 

 

IN 

Entering Edit Normal Keys mode 

Press button once 

 

OUT 

Erase All Normal keys 

Swipe Master key 

 

R blink 

OUT 

Exiting Erase All Normal Keys mode 

After 10 s 

 

R blink 

OUT 

Master key override 

The door closed, swipe 
Master key 

 

R blink 

IN 

Master key override, locker opening 

Wait 10 s 

 

R blink 

OUT 

Default state 

 

Summary of Contents for Z-395 EHT

Page 1: ...erized logging and lock setup Only works with Lock Manager software General Mode a typical lock controller operation only the key s stored in the lock s memory maximum 24 can open that lock Safe Deposit Box Mode the lock emulates safe deposit box operation To open the lock all the keys in controller database max 26 must be swipe to it one after another Custom Mode you can design your own custom op...

Page 2: ...rotection against bracelet cloning Locks setup and further use without a PC Note Logic Mode requires special Atmel T5557 keys and Lock Manager software 2 SPECIFICATIONS Working Frequency 125 kHz Keys standards EM Marine HID ProxCard II Atmel T5557 Maximum number of keys Normal 26 Master 4 NVRAM to store settings Present Reading distance 2 4 cm Standby consumption current 30 mkA Audio visual status...

Page 3: ...he locker s wall see Fig 3 4 To mark the hole positions use template from Fig 13 Fig 3 Fig 4 Self tapping Screw 3 5х15 locker s wall Self tapping Screw 3 5х25 push bolt unit Fig 2 A the calculated size depends on thickness of the locker s wall A Connect cable to lock s PCB Note Check that cable socket is firmly connected with lock s PCB socket Install the locking module according to Fig 2 Batterie...

Page 4: ...page 4 Z 395 EHT www ironlogic me How to install the Z 395 EHT lock properly Top view View from inside the door Lock s latch push bolt unit push bolt unit Lock ...

Page 5: ...ws recording the used locker number and battery level into the key bracelet Very convenient when the user forgets which locker he used Allows not to tie up the key to the lock The user will decide which of the free lockers to use Works only with Lock Manager software General mode traditional lock controller operation only the keys recorded in lock s database can open the locker Safe Deposit Box mo...

Page 6: ...s and the LED flashes green The key is erased from lock s memory the latch is withdrawn inside the lock The door is now open lock is ready to restart the cycle from the beginning Legend beep once multiple beeps G Green LED R Red LED blink blinking page 6 Z 395 EHT www ironlogic me Action Sound LED Latch What for Default state None None OUT if a Normal key is in memory Otherwise IN Waiting for Norm...

Page 7: ...er then a beep will sound green LED will flash the key will be erased from the lock s memory the latch will be draw inside the lock The door is now open lock is ready to restart the cycle from the beginning page 7 Z 395 EHT www ironlogic me Action Sound LED Latch What for Default state None None OUT if a locker is occupied otherwise IN Waiting for Normal key assignment Swipe a key G OUT Locker num...

Page 8: ...Master key 1st time R blink IN Entering Edit Normal Keys mode Swipe Master key 2nd time R blink OUT Entering Edit Normal Keys mode Swipe Master key 3rd time for 6 s R IN Entering Edit Normal Keys mode Swipe 1st 2nd 3rd Max 26th keys G IN Recording Normal Key into the controller Swipe Master key R blink OUT Exiting Add Normal Keys mode After 5 s R blink OUT Erase All Normal Keys Default state None ...

Page 9: ...Master key 1st time R blink IN Entering Edit Normal Keys mode Swipe Master key 2nd time R blink OUT Entering Edit Normal Keys mode Swipe Master key 3rd time for 6 s R IN Entering Edit Normal Keys mode Swipe 1st 2nd 3rd Max 24th keys G IN Storing Normal Key into the controller Swipe Master key R blink OUT Exiting Add Normal Keys mode After 10 s R blink OUT Erase All Normal Keys Default state None N...

Page 10: ...ns for Lock s Manager software and RF 1996 adapter can be found on the ironlogic me website 10 ERASING OF ALL MASTER KEYS This function erases all Master keys from lock s database leaving only the Normal keys intact Also cancels the currently selected operating mode To erase all Master keys please perform the following steps a Disconnect the power remove one battery or use the switch on external p...

Page 11: ...ced and the lock lacks energy to open the locker please use external power module power the lock via the connector present on the reader and swipe the lock with the key see Fig 10 Batteries are fully discharged If on Normal key swipe the LED is not flashing AND the lock s latch doesn t pop out it means that lock s batteries are fully discharged In Logic mode the lock records the current battery ch...

Page 12: ... portable computer and subsequent bracelets programming 16 OPERATING CONDITIONS Ambient temperature 5 40 C Humidity 98 at 25 C When operating under non recommended conditions device parameters can deviate from specified values 17 LIMITED WARRANTY This Device is covered by limited warranty for 24 months since the purchase date The warranty becomes void if this Manual s guidelines are not followed t...

Page 13: ...iga Latvia E mail info ironlogic lv headstaff ironlogic lv Phone 37166181894 37124422922 www ironlogic me The symbol of crossed throught waste bin on wheels means that the product must be disposed of at f separate collection point This also applies to the product and all accessories marked with this symbol Products labeled as such must not be disposed of with normal household waste but should be t...

Page 14: ...ut for Z 395 EHT installation onto a wooden chipboard locker Locker s wall 47 35 mm Locker s door Fig 13 A the size is calculated depending on locker chipboard wall thickness A Z 395 EHT www ironlogic me page 14 ...

Reviews: