10. ERAS

ING OF

 ALL MASTER KEYS

This function erases all Master keys from lock's database, leaving only the Normal keys intact. 
Also cancels the currently selected operating mode.
To erase all Master keys, please perform the following steps:
 

a.  Disconnect the power (remove one battery or use the switch on external power source,  

 

 

see Fig. 10);

 

b.  Push and hold the RESET button using a

ny

 sharp tool

;

 

c.  Connect the power (re-insert the battery or use the switch on external power source, see 

 

 

Fig. 10); continue to hold down the RESET button for 6 s until the beep and visual signal  

 

 

that will acknowledge that all Master keys have now been erased.

 

d.  After all Master keys have been erased, please 

record

 at least one Master key into lock's 

 

 

memory, so that an operational mode can be selected.

Note: Cannot choose an operational mode without a Master key!

11. RESET TO FACTORY DEFAULTS

This function resets the lock

 

into initial (factory) state. All Master and Normal keys are erased, 

the currently selected operational mode is cancelled. 
To reset to factory defaults, please perform the following steps:
 

a.  Disconnect the power (remove one battery or use the switch on external power source,  

 

 

see Fig. 10);

 

b.  Push and hold the RESET button using a

ny

 

sharp tool;

 

c.  Connect the power (re-insert the battery or use the switch on external power source, see 

 

 

Fig. 10); continue to hold down the RESET button for 16 s. The beep and visual signal will 

 

 

appear at 6 s and 16 s from the moment the RESET button was pressed down. The beep 

 

 

and visual signal at 16 s will confirm that the device is now reset to factory defaults.

12.  PROGRAMMING USING RF-1996 ADAPTER AND LOCK'S MANAGER SOFTWARE

Lock's Manager

 software along with 

RF-1996

 adapter takes care about configuration, set up 

and further operations of electronic furniture locks.

Lock's Manager

 software comprises two modules:

Edit Module

: free module that configures and sets up electronic furniture locks and keys for 

further operations.

Manager Module

: module that takes care about day-to-day site operation. Manages keys  

 

and records attendance, monitors staff operations, provides periodic reports, monitors the  

 

used lockers numbers, provides the user info-kiosk function (will remind the user the locker  

 

number in case they forgot), controls the battery levels in the locks, protects against    

 

fraudulent card cloning. Works only in Logic Mode and with 

Atmel (T5557)

 keys.

Programming works as follows:

Install Edit Module

 onto a laptop (required, so it can be taken to every lock on site for  

 

programming).

-  Connect an 

RF-1996

 adapter to the laptop.

Select operational mode

Record

 a Master card.

Swipe 

 the 

RF-1996

 adapter to the lock's reader, to 

record

 the selected operational mode

 

and 

Master card into that lock via contactless technology. The transmission takes 2…3 s after  
the laptop has been connected to the lock.

Detailed instructions for 

Lock's Manager

 software

 

and 

RF-1996

 adapter can be found on the   

ironlogic.me 

website

.

Z-

395

 EHT

www.ironlogic.

me

Summary of Contents for Z-395 EHT

Page 1: ...erized logging and lock setup Only works with Lock Manager software General Mode a typical lock controller operation only the key s stored in the lock s memory maximum 24 can open that lock Safe Deposit Box Mode the lock emulates safe deposit box operation To open the lock all the keys in controller database max 26 must be swipe to it one after another Custom Mode you can design your own custom op...

Page 2: ...rotection against bracelet cloning Locks setup and further use without a PC Note Logic Mode requires special Atmel T5557 keys and Lock Manager software 2 SPECIFICATIONS Working Frequency 125 kHz Keys standards EM Marine HID ProxCard II Atmel T5557 Maximum number of keys Normal 26 Master 4 NVRAM to store settings Present Reading distance 2 4 cm Standby consumption current 30 mkA Audio visual status...

Page 3: ...he locker s wall see Fig 3 4 To mark the hole positions use template from Fig 13 Fig 3 Fig 4 Self tapping Screw 3 5х15 locker s wall Self tapping Screw 3 5х25 push bolt unit Fig 2 A the calculated size depends on thickness of the locker s wall A Connect cable to lock s PCB Note Check that cable socket is firmly connected with lock s PCB socket Install the locking module according to Fig 2 Batterie...

Page 4: ...page 4 Z 395 EHT www ironlogic me How to install the Z 395 EHT lock properly Top view View from inside the door Lock s latch push bolt unit push bolt unit Lock ...

Page 5: ...ws recording the used locker number and battery level into the key bracelet Very convenient when the user forgets which locker he used Allows not to tie up the key to the lock The user will decide which of the free lockers to use Works only with Lock Manager software General mode traditional lock controller operation only the keys recorded in lock s database can open the locker Safe Deposit Box mo...

Page 6: ...s and the LED flashes green The key is erased from lock s memory the latch is withdrawn inside the lock The door is now open lock is ready to restart the cycle from the beginning Legend beep once multiple beeps G Green LED R Red LED blink blinking page 6 Z 395 EHT www ironlogic me Action Sound LED Latch What for Default state None None OUT if a Normal key is in memory Otherwise IN Waiting for Norm...

Page 7: ...er then a beep will sound green LED will flash the key will be erased from the lock s memory the latch will be draw inside the lock The door is now open lock is ready to restart the cycle from the beginning page 7 Z 395 EHT www ironlogic me Action Sound LED Latch What for Default state None None OUT if a locker is occupied otherwise IN Waiting for Normal key assignment Swipe a key G OUT Locker num...

Page 8: ...Master key 1st time R blink IN Entering Edit Normal Keys mode Swipe Master key 2nd time R blink OUT Entering Edit Normal Keys mode Swipe Master key 3rd time for 6 s R IN Entering Edit Normal Keys mode Swipe 1st 2nd 3rd Max 26th keys G IN Recording Normal Key into the controller Swipe Master key R blink OUT Exiting Add Normal Keys mode After 5 s R blink OUT Erase All Normal Keys Default state None ...

Page 9: ...Master key 1st time R blink IN Entering Edit Normal Keys mode Swipe Master key 2nd time R blink OUT Entering Edit Normal Keys mode Swipe Master key 3rd time for 6 s R IN Entering Edit Normal Keys mode Swipe 1st 2nd 3rd Max 24th keys G IN Storing Normal Key into the controller Swipe Master key R blink OUT Exiting Add Normal Keys mode After 10 s R blink OUT Erase All Normal Keys Default state None N...

Page 10: ...ns for Lock s Manager software and RF 1996 adapter can be found on the ironlogic me website 10 ERASING OF ALL MASTER KEYS This function erases all Master keys from lock s database leaving only the Normal keys intact Also cancels the currently selected operating mode To erase all Master keys please perform the following steps a Disconnect the power remove one battery or use the switch on external p...

Page 11: ...ced and the lock lacks energy to open the locker please use external power module power the lock via the connector present on the reader and swipe the lock with the key see Fig 10 Batteries are fully discharged If on Normal key swipe the LED is not flashing AND the lock s latch doesn t pop out it means that lock s batteries are fully discharged In Logic mode the lock records the current battery ch...

Page 12: ... portable computer and subsequent bracelets programming 16 OPERATING CONDITIONS Ambient temperature 5 40 C Humidity 98 at 25 C When operating under non recommended conditions device parameters can deviate from specified values 17 LIMITED WARRANTY This Device is covered by limited warranty for 24 months since the purchase date The warranty becomes void if this Manual s guidelines are not followed t...

Page 13: ...iga Latvia E mail info ironlogic lv headstaff ironlogic lv Phone 37166181894 37124422922 www ironlogic me The symbol of crossed throught waste bin on wheels means that the product must be disposed of at f separate collection point This also applies to the product and all accessories marked with this symbol Products labeled as such must not be disposed of with normal household waste but should be t...

Page 14: ...ut for Z 395 EHT installation onto a wooden chipboard locker Locker s wall 47 35 mm Locker s door Fig 13 A the size is calculated depending on locker chipboard wall thickness A Z 395 EHT www ironlogic me page 14 ...

Reviews: