1.0 System Installation 

1.1 System Components 
1.2 Pairing the EntryPad with the Lock(s) 
1.3 Lock and EntryPad Installation 
1.4 Installing Battery 
1.5 Test Lock Operation 

 
2.0 Code Length Options

 

2.1 PW L – 6 / Users 10 
2.2 PW L – 8 / Users 30 
2.3 PW L – 6 / Users 30 

 
3.0 Lock Operation

 

3.1 Opening the Lock 
3.2 Opening the Lock in Time Delay 
3.3 Opening the Lock Under Duress 
3.4 Opening the Lock in Dual Control 
3.5

 

Opening the Lock with a Multi-Lock System 

 
4.0 Set Date and Time

 

4.1 Set Clock Time 
4.2 Show Clock Time 
4.3 DayLight Savings Time 

 
5.0 Code Management

 

5.1 Enrolling New Users 
5.2 Change Code 
5.3 Delete One User 
5.4 Delete All Users 
5.5 Disable/Enable User 
5.6 Obfuscate Code Entry 
5.7 Set ID01 to Master 
 

6.0 System Identification

 

6.1 System Info 

 
7.0 Time Delay

 

7.1 Set/Cancel Time Delay 

 
8.0 Audit Trail Functionality

 

8.1 Show Audit Trail 
 

9.0 Manager Mode 

9.1 Enable Manager Mode 
9.2 Disable Manager Mode 

 
10.0 Single or Dual Control

 

10.1 Enable Dual Mode 
10.2 Dual Mode Group ID 

 
11.0 Door Management

 

11.1 Max. Door Open Time 
11.2 Configuring a Multi-lock system 
11.3 Set Number of Locks 
11.4 Numbering Locks 
11.5 Authorize Locks 
11.6 Enable Sequence 

 
12.0 Duress Management

 

12.1 Duress Setup and Wiring Configuration 
12.2 Duress Code Shift 

 
13.0 Device Management

 

13.1 Set Device ID 

 
14.0 Data Management 

14.1 Encryption Key Set 

 
15.0 Recovering the System – Reset to Default

 

15.1 Recovery Code Set 
15.2 Recover System 
15.3 Disable Recover 
15.4 Mechanical Reset 

 
16.0 System Testing 

16.1 Cycle Testing 
16.2 Hardware Testing 

 
17.0 Menus 

17.1 The ProLogic L22 Menus 

 

Summary of Contents for ProLogic L22

Page 1: ... Delete All Users 5 5 Disable Enable User 5 6 Obfuscate Code Entry 5 7 Set ID01 to Master 6 0 System Identification 6 1 System Info 7 0 Time Delay 7 1 Set Cancel Time Delay 8 0 Audit Trail Functionality 8 1 Show Audit Trail 9 0 Manager Mode 9 1 Enable Manager Mode 9 2 Disable Manager Mode 10 0 Single or Dual Control 10 1 Enable Dual Mode 10 2 Dual Mode Group ID 11 0 Door Management 11 1 Max Door O...

Page 2: ... being used with the lock body The ProLogic L22 is a digital lock system and therefore the lock must also be programmed in digital mode Both modes follow the same steps to reset set which is done by following the steps detailed below Step 1 Ensure the battery is connected to the EntryPad Step 2 Ensure the lock cable is disconnected from the lock body Step 3 Locate the Reset Hole on the back of the...

Page 3: ...ts on the safe door in the pre drilled holes above and below the spindle hole Now insert the lock cable attached to the EntryPad through the spindle hole On the backside of the safe door you will see the lock mounting plate and the predrilled lock mounting holes Connect the lock cable to the lock body and position the lock body appropriately on the lock mounting plate Ensure that the lock cable is...

Page 4: ...2 Installing the Battery SureLock Battery Compartment removable battery compartment Locate the SureLock Battery Compartment at the 5 o clock position of the EntryPad See Fig 3 Release the latch of the battery compartment by pulling lever downward See Fig 4 Pull out the battery compartment from the bottom of the EntryPad See Fig 5 Install a new 9V alkaline battery Duracell or Energizer brands are r...

Page 5: ...quired on all lock bodies All programming will be deleted and the lock will be set back to default There are 3 options available as follows Code Length 6 digits 10 total codes available This is the default mode and meets the UL requirement Code Length 8 digits 30 total codes available This mode also meets the UL requirement Code Length 6 digits 30 total codes available This mode does not meet the ...

Page 6: ... be 1 2 3 4 5 6 The Default Recovery Code will be 9 9 9 9 9 9 The Default Encryption Code will be 6 8 5 1 9 8 2 2 PW L 8 Users 30 NOTE This operation must be performed with the SAFE DOOR OPEN and with access to the back of the lock as a mechanical reset must be performed during this programming sequence Step1 Press the Menu OK button Step 2 Using the and scroll to the System Menu and Press Menu OK...

Page 7: ...1 2 3 4 5 6 0 0 The Default Recovery Code will be 9 9 9 9 9 9 0 0 The Default Encryption Code will be 6 8 5 1 9 8 0 0 2 3 PW L 6 Users 30 NOTE This operation must be performed with the SAFE DOOR OPEN and with access to the back of the lock as a mechanical reset must be performed during this programming sequence Step1 Press the Menu OK button Step 2 Using the and scroll to the System Menu and Press...

Page 8: ...al Reset procedure outlined in 15 4 Mechanical Reset The code length will now be 6 digits and the total available users will be 30 This mode is not certified by UL The Super Code ID00 will now be 1 1 1 1 1 1 The Manager Code ID01 will now be 1 2 3 4 5 6 The Default Recovery Code will be 9 9 9 9 9 9 The Default Encryption Code will be 6 8 5 1 9 8 3 0 Lock Operation Upon initial power up the LCD scr...

Page 9: ...ager Code ID01 1 2 3 4 5 6 Step 1 Enter a valid code for example ID00 The display will read ID00 Verified And the Lock will open The display will read The lock will relock after 6 seconds Note Time to relock is hard coded and cannot be changed 3 2 Opening Lock with Time Delay Programmed When Time Delay has been programmed the user must enter a valid code Note Users are defined as ID03 ID30 Wait th...

Page 10: ...ogic L22 has a Duress Feature which allows a User or Admin to open the lock and send a silent Duress signal indicating that you are in danger By default the duress function is active It can be disabled by changing the Duress Code Shift Value to 00 Refer to Section 12 2 In Order to send a signal the system must have a CB10 junction box installed and must be connected to an alarm panel To Open the L...

Page 11: ...e will read ID04 Verified The lock will open and relock in 6 seconds 3 5 Opening the Lock with a Multi Lock System The ProLogic L22 can operate up to 4 locks See 11 2 Configuring a Multi Lock System to set up this option To Open a Lock with a Multi Lock System Step 1 Enter a valid code The display will read IDXX Verified Step 2 The system will now prompt you to select the number of the Lock to be ...

Page 12: ... date and time will flash when it is available to be set Use the and to scroll to the correct value and Press OK to move to the next element 4 2 Show Clock Time Step1 Press the Menu OK button Step 2 Using the and scroll to the System Menu and press OK Step 3 The display will prompt you to enter a valid code Enter either the Super Code ID00 or the Manager Code ID01 The Select Menu message will be d...

Page 13: ...The display will prompt you to enter a valid code Enter either the Super Code ID00 or the Manager Code ID01 The Select Menu message will be displayed as follows Step 4 Scroll to the menu selection Daylight Savings TM and Press OK Step 5 Press the button to turn Daylight Savings Time Management on To turn it off press the button Step 6 Starting Month The system will now request the month in which D...

Page 14: ...p 11 Ending Time The system will now request the Time on the first day of the week Sunday at which Daylight Savings Time is to end The default is North American DST Time 2 2 00am To change Press the and to set the Week and press OK Therefore to set to the North American DST just select Y on the first display screen and then accept the defaults for all other settings by pressing OK 5 0 Code Managem...

Page 15: ...essage will be displayed as follows Step 4 Scroll to the menu selection Enroll New User and Press OK Step 5 The next available ID position is displayed To select this ID Press OK or to select a different ID position Press to desired ID and press OK Step 6 Now enter a 6 digit code Step 7 Repeat new code Step 8 System will verify that code has been saved The new code is now enrolled and available to...

Page 16: ...DXX to be changed Step 6 Enter the new 6 digit code Step 7 Repeat the new code The New Code has now been saved and is available for use 5 3 Delete One User Step1 Press the Menu OK button Step 2 Using the and scroll to the System Menu and Press Menu OK Step 3 The display will prompt you to enter a valid code Enter either the Super Code ID00 or the Manager Code ID01 or ID02 The Select Menu message w...

Page 17: ...fault The Recover System function is used to reset the Super Code to default Step1 Press the Menu OK button Step 2 Using the and scroll to the System Menu and Press Menu OK Step 3 The display will prompt you to enter a valid code Enter either the Super Code ID00 or the Manager Code ID01 or ID02 The Select Menu message will be displayed as follows Step 4 Scroll UP to the menu selection Delete All U...

Page 18: ...r the Manager Code ID01 or ID02 The Select Menu message will be displayed as follows Step 4 Scroll and to the menu selection Disable User and Press OK Step 5 The system will ask which User to disable Scroll and to the desired USER ID and press OK Step 6 The system will verify the User has been disabled 5 6 Obfuscate Code Entry This feature would be used in order to obfuscate the code as it is ente...

Page 19: ... this mode follow the same process but select Show Code Entry 5 7 Set ID01 to Master This programming command would be used in order to establish a hierarchy within the Manager ID01 Supervisor ID02 code permissions When Set ID01 to Master is enabled ID02 cannot Delete ID01 ID02 cannot Disable ID01 ID02 Manager functions are removed from the System Menu ID02 can ONLY o Enroll New User o Delete One ...

Page 20: ... select Set ID01 to Manager and the management menu will be restored to default for ID02 6 0 System Info System Identification This menu feature would be used to determine the type of safe lock system being used Many of the SecuRam ProLogic EntryPads look the same but the features sets and capabilities vary greatly depending upon the software being utilized To determine the type of ProLogic Safe L...

Page 21: ...u OK Step 3 The display will prompt you to enter a valid code Enter either the Super Code ID00 or the Manager Code ID01 or ID02 The Select Menu message will be displayed as follows Step 4 Scroll UP to the menu selection Set Cancel Time Delay and Press OK Step 5 Press the and to adjust the Time Delay value 0 99 minutes Press OK Step 6 The system will now display the Time Window This is the preset l...

Page 22: ...elay Override Users Step 6 Press OK When TDO is set to ID00 only ID00 and ID01 have TDO authority By default ID02 is selected as TDO 8 0 Audit Trail Functionality The ProLogic L22 records 200 date and time stamped audit trail events It stores the most recent 200 events and overwrites the oldest first The Audit Trail can be viewed on the LCD screen only 8 1 Show Audit Trail Step1 Press the Menu OK ...

Page 23: ...When this mode is enabled the Manager Codes ID01 and ID02 are not used to open the safe When entered these codes alternately toggle on off the User Codes For example the User codes have been enabled all day but now the Manager is closing the store for the night The Manager enters the ID01 or ID02 code this action does not open the safe but instead it toggles off disables all User Codes ID03 30 ID0...

Page 24: ...is used to toggle on off all User codes ID01 still has all its programming functions ID02 Code cannot open the safe and is used to toggle on off all User codes ID02 managerial programming functions have been disabled 9 2 Disable Manager Mode This menu selection allows you to set the Manager Mode as described above Step1 Press the Menu OK button Step 2 Using the and scroll to the System Menu and Pr...

Page 25: ... valid code Enter either the Super Code ID00 or the Manager Code ID01 or ID02 The Select Menu message will be displayed as follows Step 4 Scroll to the menu selection Enable Dual Mode and Press OK Step 5 Press OK Dual Mode has now been enabled Two valid codes will be required to open the safe lock system ID00 ID01 and ID02 are Dual Mode Override Codes If you want to remove Dual Mode Override capab...

Page 26: ...s If you set this number to 00 the function is turned off or disabled and normal Dual Mode rules apply any two valid codes can be entered to open the lock and the Management Code ID00 ID01 ID02 are Dual Mode Override Codes NOTE If the ProLogic is set to PW L 6digits and 10 Users this number will be defaulted to 5 not 15 Step1 Press the Menu OK button Step 2 Using the and scroll to the System Menu ...

Page 27: ... order to turn off this feature Enter 00 in this menu 11 2 Configuring a Multi Lock system The ProLogic L22 is capable of managing 4 locks A CB11 1T4 is required to operate 4 locks with the ProLogic L22 EntryPad In order to manage more than one lock you need to tell the system how many locks are connected and then identify the locks with a number see Section 9 3 How to Number and Add Locks Users c...

Page 28: ...oLogic L22 EntryPad to the CB11 1T4 Junction box in port J0 Step 2 Perform a mechanical reset on your first lock and connect it to any open port on the Junction box Step 3 Enter a valid code and it will ask you Select Lock Select 1 4 to name the lock If you press 1 this lock will be named Lock 1 If you press 2 the lock will be named Lock 2 etc Step 4 Repeat the process to add more locks Remember t...

Page 29: ...to the desired User ID Step 6 Now select the uppermost User ID to be authorized Use the and to navigate to the desired User ID Press OK Step 7 Next the LCD will display the current settings for these users In the example below this group of users is authorized to open Lock 1 but it does not have access to Locks 2 3 or 4 An O means that Lock can be Opened while an X means the lock is not authorized...

Page 30: ...or is selected to be opened Lock 1 will open and then 3 seconds later the selected inner compartment lock will open 12 0 Duress Management The ProLogic L22 offers Duress functionality In the event of a burglary or specifically a hold up at your place of business where the culprit demands entrance to the safe Users can provide entrance to the safe By entering his her own code plus 1 number or minus...

Page 31: ...ll prompt you to enter a valid code Enter the Super Code ID00 This function is not available in the menu accessed by the Manager Code ID01 The Select Menu message will be displayed as follows Step 4 Scroll to the menu selection Duress Code Shift and Press OK Step 5 Using the numbers on the EntryPad enter 00 and press OK Duress code is now disabled and a valid code entered 1 digit will show as an i...

Page 32: ...e from the EntryPad to the lock such as User codes 14 1 Encryption Key Set The ProLogic L22 sends and receives data to the lock in an encrypted form This is a security measure to ensure that all data is protected The Encryption Key is set during the manufacturing process with a default encryption key value This value can be changed using the Encryption Key Set menu selection Note If the Encryption...

Page 33: ...n Code Generator Software The alpha numeric code is entered into the software together with the encryption code Through the software these codes are deciphered to generate a One Time Use Reset Code When entered into the ProLogic safe lock the lock and EntryPad are reset to factory default and the system is recovered Once used the OTC One Time Code is no longer valid There is no limit to the number...

Page 34: ... Authorization Code This code remains valid for a period of 20 minutes only Step 7 After receiving the One Time Use Authorization Code from the Recovery Center press the back button and you will be prompted to enter your Authorization Code Step 8 Next you will be prompted to enter your new 6 digit 8 digit Recovery Code Step 9 Repeat the 6 digit 8 digit Recovery Code The new Recovery Code has now b...

Page 35: ...tep 3 The display will prompt you to enter the Recovery Code Enter the existing Recovery Code The default recovery Code is 999999 PW L 6 Users 10 or PW L 6 Users 30 or 99999900 PW L 8 Users 30 Step 4 The LCD screen will display an alpha numeric number random key Record this number and call an authorized SecuRam Recovery Center or SecuRam Tech Support at 1 805 988 8088 This Key Code remains valid f...

Page 36: ...p 3 The display will prompt you to enter a valid code Enter either the Super Code ID00 This function is not available to the Manager Code holders ID01 ID02 The Select Menu message will be displayed as follows Step 4 Scroll to the menu selection Disable Recovery and Press OK The Recovery Option will now be disabled 15 4 Mechanical Reset SecuRam Safe Locks can operate in either Analog mode or Digita...

Page 37: ...that the EntryPad is not connected to the lock and that the battery is connected to the EntryPad Step 2 Find the reset hole on the back of the lock under the QC sticker Step 3 Using a poke tool depress the reset button on the back of the lock 3 times This discharges any latent energy within the lock s capacitors Step 4 Depress the reset button and hold it in its depressed position While the reset ...

Page 38: ...rmance SecuRam offers this unique menu selection that allows you to test the lock system performance through actual Cycle Testing The Hardware Testing menu selection is not available for field use It is however used in the manufacturing process to check the board level components 16 1 Cycle Testing In order to perform a cycle test on the ProLogic system follow these steps Step1 Press the Menu OK b...

Page 39: ...er Codes ID01 and 02 have access to the all programming menus User Codes have limited menu selections ProLogic L22 Menu Root Menu Select Menu System Menu System Info Show Clock Time Recovery Code Set Recover System Encryption Key Set Sub Menu Super Manager Codes Select Menu Change Code Show Audit Trail System Info Show Clock Time Day Light Savings TM Set Clock Time Max Door Open Time Set TDO User ...

Page 40: ...regarding UL certification The audit features duress features peripheral devices and accessories software features and other additional features have not been evaluated by UL as these functions are beyond the scope of the UL certification program ...