Assembly guide for EASY ROOF EVOLUTION L-1
In
fo
rm
at
io
n
et
v
is
u
el
s
n
o
n
c
o
n
tr
ac
tu
el
s.
S
o
u
s
rés
er
ve
d
e
m
o
d
if
ic
at
io
n
s
tec
h
n
iq
u
es
s
an
s
p
réavi
s.
This document is the property of IRFTS. It shall not be reproduced or shared with third parties without IRFTS agreement
12.1.3)
2°) Set up the bottom
flashing
batten
at
10 mm MAXIMUM to the top of the tile .
Use the wood (G)
and (K) defined in the preceding operation. Put the batten (e) against the batten (g).
Screw
with
stainless
screws
5x60 milled head.
* Reference nomenclature
Model “L-1” 60 Cells 6” Portrait
3°) Set up the first reference support batten d*.
Position this support batten 435 mm to the break of
the bottom
flashing
flooring. (equal to 435mm + A from the top of the tile)
Screw the support batten
following the recommendations page 21 to 24 to know the type and the
number of screws to be
used.
Installation of the bottom
flashing support batten
and
the reference
support batten.
The bottom
flashing
batten and the
bottom
flashing
itself will have to be
2 tiles longer on each side of the PV
field.
0°
1°) Determination of dimension A (Bottom
flashing
batten)
The « C » dimension is the Minimum batten
width
necessary to avoid reverse slope on the bottom
flashing. It’s possible to use a wider
batten, this
will
simply
raise up the PV field.
(G)
(K)
(F)
Reference support batten(d)*
26
PV field
centered on rake direction
Reverse slope FORBIDDEN
Roof slope
(°)
Minimum batten
width
dimensionC
MINI (mm)
Dimension A Mini
(mm)
10 à 12
250
260
13 à 16
220
230
17 à 19
180
190
20 à 24
150
160
25 à 50
120
130
(e)